Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;64(3):514-524.
doi: 10.1109/TUFFC.2016.2634329. Epub 2016 Dec 1.

A Frequency-Shift Method to Measure Shear-Wave Attenuation in Soft Tissues

A Frequency-Shift Method to Measure Shear-Wave Attenuation in Soft Tissues

Simon Bernard et al. IEEE Trans Ultrason Ferroelectr Freq Control. 2017 Mar.

Abstract

In vivo quantification of shear-wave attenuation in soft tissues may help to better understand human tissue rheology and lead to new diagnostic strategies. Attenuation is difficult to measure in acoustic radiation force elastography because the shear-wave amplitude decreases due to a combination of diffraction and viscous attenuation. Diffraction correction requires assuming a cylindrical wavefront and an isotropic propagation medium, which may not be the case in some applications. In this paper, the frequency-shift method, used in ultrasound imaging and seismology, was adapted for shear-wave attenuation measurement in elastography. This method is not sensitive to diffraction effects. For a linear frequency dependence of the attenuation, a closed-form relation was obtained between the decrease in the peak frequency of the gamma-distributed wave amplitude spectrum and the attenuation coefficient of the propagation medium. The proposed method was tested against a plane-wave reference method in homogeneous agar-gelatin phantoms with 0%, 10%, and 20% oil concentrations, and hence different attenuations of 0.117, 0.202, and 0.292 [Formula: see text]/Hz, respectively. Applicability to biological tissues was demonstrated with two ex vivo porcine liver samples (0.79 and 1.35 [Formula: see text]/Hz) and an in vivo human muscle, measured along (0.43 [Formula: see text]/Hz) and across (1.77 [Formula: see text]/Hz) the tissue fibers. In all cases, the data supported the assumptions of a gamma-distributed spectrum for the source and linear frequency attenuation for the tissue. This method provides tissue attenuation, which is relevant diagnostic information to model viscosity, in addition to shear-wave velocity used to assess elasticity. Data processing is simple and could be performed automatically in real time for clinical applications.

PubMed Disclaimer

Publication types

LinkOut - more resources