Abstract
Background: The Trinity Biotech Uni-Gold HIV test (Uni-Gold) is often used as a supplementary rapid test in testing algorithms.
Objective: To evaluate the operational performance of the Uni-Gold as a first-line screening test among gay and bisexual men (GBM) in a setting where 4th generation HIV laboratory assays are routinely used.
Study design: We compared the performance of Uni-Gold with conventional HIV serology conducted in parallel among GBM attending 22 testing sites. Sensitivity was calculated separately for acute and established infection, defined using 4th generation screening Ag/Ab immunoassay (EIA) and Western blot results. Previous HIV testing history and results of supplementary 3rd generation HIV Ab EIA, and p24 antigen EIA were used to further characterise cases of acute infection.
Results: Of 10,793 specimens tested with Uni-Gold and conventional serology, 94 (0.90%, 95%CI:0.70-1.07) were confirmed as HIV-positive by conventional serology, and 37 (39.4%) were classified as acute infection. Uni-Gold sensitivity was 81.9% overall (77/94, 95%CI:72.6-89.1); 56.8% for acute infection (21/37, 95%CI:39.5-72.9) and 98.2% for established infection (56/57, 95%CI:90.6-100.0). Of 17 false non-reactive Uni-Gold results, 16 were acute infections, and of these seven were p24 antigen reactive but antibody negative. Uni-Gold specificity was 99.9% (10,692/10,699, 95%CI:99.9-100.0), PPV was 91.7% (95%CI:83.6-96.6) and NPV was 99.8% (95%CI:99.7-99.9), respectively.
Conclusions: In this population, Uni-Gold had good specificity and sensitivity was high for established infections when compared to 4th generation laboratory assays, however sensitivity was lower in acute infections. Where rapid tests are used in populations with a high proportion of acute infections, additional testing strategies are needed to detect acute infections.
Keywords: 3rd generation immunoassay; 4th generation immunoassay; Acute HIV infection; Performance; Rapid HIV test; p24 antigen.
Copyright © 2016 Elsevier B.V. All rights reserved.
Similar articles
-
Comparison of turnaround time and total cost of HIV testing before and after implementation of the 2014 CDC/APHL Laboratory Testing Algorithm for diagnosis of HIV infection.J Clin Virol. 2017 Jun;91:69-72. doi: 10.1016/j.jcv.2017.04.004. Epub 2017 Apr 6. J Clin Virol. 2017. PMID: 28461133
-
Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur.J Clin Virol. 2013 Dec;58 Suppl 1:e79-84. doi: 10.1016/j.jcv.2013.08.009. J Clin Virol. 2013. PMID: 24342482
-
Performances of fourth generation HIV antigen/antibody assays on filter paper for detection of early HIV infections.J Clin Virol. 2015 Jan;62:92-7. doi: 10.1016/j.jcv.2014.11.005. Epub 2014 Nov 13. J Clin Virol. 2015. PMID: 25464967
-
Sensitivity of HIV rapid tests compared with fourth-generation enzyme immunoassays or HIV RNA tests.AIDS. 2016 Jul 31;30(12):1951-60. doi: 10.1097/QAD.0000000000001134. AIDS. 2016. PMID: 27124900
-
HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites.J Int AIDS Soc. 2017 Jul 3;20(1):21419. doi: 10.7448/IAS.20.1.21419. J Int AIDS Soc. 2017. PMID: 28691437 Free PMC article. Review.
Cited by
-
Longitudinal patterns in indeterminate HIV rapid antibody test results: a population-based, prospective cohort study.Microbiol Spectr. 2024 Feb 6;12(2):e0325323. doi: 10.1128/spectrum.03253-23. Epub 2024 Jan 8. Microbiol Spectr. 2024. PMID: 38189332 Free PMC article.
-
A handheld HIV detection platform using paper-based sample preparation and real-time isothermal amplification.Microsyst Nanoeng. 2024 Nov 29;10(1):181. doi: 10.1038/s41378-024-00822-1. Microsyst Nanoeng. 2024. PMID: 39613739 Free PMC article.
-
Trial and error: evaluating and refining a community model of HIV testing in Australia.BMC Health Serv Res. 2017 Oct 10;17(1):692. doi: 10.1186/s12913-017-2635-z. BMC Health Serv Res. 2017. PMID: 29017561 Free PMC article.
-
Subtype-specific differences in transmission cluster dynamics of HIV-1 B and CRF01_AE in New South Wales, Australia.J Int AIDS Soc. 2021 Jan;24(1):e25655. doi: 10.1002/jia2.25655. J Int AIDS Soc. 2021. PMID: 33474833 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical