Reliability of cutaneous oxygen measurement by skin sensors with large-size cathodes
- PMID: 279196
- DOI: 10.1111/j.1399-6576.1978.tb01388.x
Reliability of cutaneous oxygen measurement by skin sensors with large-size cathodes
Abstract
The oxygen partial pressure may be measured cutaneously by directly heated PO2 sensors attached to the surface of the skin. The use of a large-size cathods (diameter 4 mm) allows one to obtain an average PO2 value over a sufficiently large skin area. The permeability of the membrane for oxygen has to be kept low to prevent a disturbance of the oxygen profile in the cutaneous tissue as a result of the oxygen consumption of the sensor. When using of 6 micrometer Mylar membrane, the current can be limited by the diffusion of oxygen through the membrane and is a measure of the arterialized cutaneous PO2. One effect of using membrane of low permeability is that the response time of the sensor is long (tau 90% = ca 45 sec). The reliability of correctly reproducing cPO2 variations by sensors having different response times may be evaluated by determining the transfer function of the membrane which allows the calculation of the frequency characteristics for various membranes. The cutaneous tissue layer also acts as a filter for rapid PO2 fluctuations. The characteristic of this filter is essentially similar to that of a "slow" membrane such as Myler 6 micrometer. The information gained by using a "rapid" membrane such as Telfon 13 micrometer is negligible. In 490 comparative measurements in newborns performed with sensors heated to 44 degree C, the correlation between arterial PO2 and cutaneously measured PO2 is significant (correlation coefficient = 0.934) and the regression line does not deviate significantly from the identity line.
Similar articles
-
Measurement of heated skin O2 diffusion conductance and PO2 sensor induced O2 gradient.Acta Anaesthesiol Scand Suppl. 1978;68:1-3. Acta Anaesthesiol Scand Suppl. 1978. PMID: 279189
-
Skin sensors for continuous oxygen monitoring of newborns.Biotelemetry. 1977;4(2):48-76. Biotelemetry. 1977. PMID: 610772
-
Characteristics of non-aqueous electrolytes for transcutaneous oxygen electrodes.Acta Anaesthesiol Scand Suppl. 1978;68:49-54. doi: 10.1111/j.1399-6576.1978.tb01392.x. Acta Anaesthesiol Scand Suppl. 1978. PMID: 279200
-
Blood flow rate, temperature, oxygen tension and consumption in the skin of adults measured by a heated microcathode oxygen electrode.Dan Med Bull. 1988 Aug;35(4):322-34. Dan Med Bull. 1988. PMID: 3048920 Review.
-
Transcutaneous PO2 measurement.Can Anaesth Soc J. 1984 Nov;31(6):664-77. doi: 10.1007/BF03008765. Can Anaesth Soc J. 1984. PMID: 6388743 Review.
Cited by
-
Home monitoring of transcutaneous oxygen tension in the early detection of hypoxaemia in infants and young children.Arch Dis Child. 1991 Jun;66(6):676-82. doi: 10.1136/adc.66.6.676. Arch Dis Child. 1991. PMID: 2053785 Free PMC article. Clinical Trial.