An in vivo pilot study of a microporous thin film nitinol-covered stent to assess the effect of porosity and pore geometry on device interaction with the vessel wall
Abstract
Sputter-deposited thin film nitinol constructs with various micropatterns were fabricated to evaluate their effect on the vessel wall in vivo when used as a covering for commercially available stents. Thin film nitinol constructs were used to cover stents and deployed in non-diseased swine arteries. Swine were sacrificed after approximately four weeks and the thin film nitinol-covered stents were removed for histopathologic evaluation. Histopathology revealed differences in neointimal thickness that correlated with the thin film nitinol micropattern. Devices covered with thin film nitinol with a lateral × vertical length = 20 × 40 µm diamond pattern had minimal neointimal growth with well-organized cell architecture and little evidence of ongoing inflammation. Devices covered with thin film nitinol with smaller fenestrations exhibited a relatively thick neointimal layer with inflammation and larger fenestrations showed migration of inflammatory and smooth muscle cells through the micro fenestrations. This "proof-of-concept" study suggests that there may be an ideal thin film nitinol porosity and pore geometry to encourage endothelialization and incorporation of the device into the vessel wall. Future work will be needed to determine the optimal pore size and geometry to minimize neointimal proliferation and in-stent stenosis.
Keywords: Coronary artery disease; neointimal hyperplasia; peripheral artery disease; restenosis; thin film nitinol.
Similar articles
-
Comparison of a microporous thermoplastic polyurethane-covered stent with a self-expanding bare nitinol stent in a porcine iliac artery model.J Vasc Interv Radiol. 2009 Jul;20(7):927-35. doi: 10.1016/j.jvir.2009.04.044. Epub 2009 Jun 4. J Vasc Interv Radiol. 2009. PMID: 19497761
-
Thin film nitinol covered stents: design and animal testing.ASAIO J. 2008 May-Jun;54(3):221-6. doi: 10.1097/MAT.0b013e31816b43b0. ASAIO J. 2008. PMID: 18496269
-
An overview of thin film nitinol endovascular devices.Acta Biomater. 2015 Jul;21:20-34. doi: 10.1016/j.actbio.2015.03.025. Epub 2015 Mar 31. Acta Biomater. 2015. PMID: 25839120 Review.
-
Super hydrophilic thin film nitinol demonstrates reduced platelet adhesion compared with commercially available endograft materials.J Surg Res. 2011 Nov;171(1):317-22. doi: 10.1016/j.jss.2010.01.014. Epub 2010 Feb 4. J Surg Res. 2011. PMID: 20451925
-
Evolving modalities for femoropopliteal interventions.J Endovasc Ther. 2009 Apr;16(2 Suppl 2):II82-97. doi: 10.1583/08-2654.1. J Endovasc Ther. 2009. PMID: 19624076 Review.
Cited by
-
The Potential Impact and Timeline of Engineering on Congenital Interventions.Pediatr Cardiol. 2020 Mar;41(3):522-538. doi: 10.1007/s00246-020-02335-w. Epub 2020 Mar 20. Pediatr Cardiol. 2020. PMID: 32198587 Review.
-
Biomimetic and Bioactive Small Diameter Tubular Scaffolds for Vascular Tissue Engineering.Biomimetics (Basel). 2022 Nov 14;7(4):199. doi: 10.3390/biomimetics7040199. Biomimetics (Basel). 2022. PMID: 36412727 Free PMC article.
-
Nitinol thin films functionalized with CAR-T cells for the treatment of solid tumours.Nat Biomed Eng. 2020 Feb;4(2):195-206. doi: 10.1038/s41551-019-0486-0. Epub 2019 Dec 9. Nat Biomed Eng. 2020. PMID: 31819155
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources