Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jul;32(7):1363-1369.
doi: 10.1111/jgh.13671.

Application of the combined FibroMeter vibration-controlled transient elastography algorithm in Chinese patients with non-alcoholic fatty liver disease

Affiliations

Application of the combined FibroMeter vibration-controlled transient elastography algorithm in Chinese patients with non-alcoholic fatty liver disease

Thomson Chi-Wang Loong et al. J Gastroenterol Hepatol. 2017 Jul.

Abstract

Background and aim: The FibroMeter vibration-controlled transient elastography (FM VCTE) is a new formula combining the serum test FM and liver stiffness measurement (LSM) by VCTE. We tested the accuracy and utility of FM VCTE for fibrosis staging in patients with non-alcoholic fatty liver disease (NAFLD).

Methods: Two hundred fifteen NAFLD patients with LSM, FM NAFLD, FM VCTE, and other serum tests (aspartate aminotransferase-to-platelet ratio index, fibrosis-4 index, BARD score, NAFLD fibrosis score, and aspartate aminotransferase-to-alanine aminotransferase ratio) performed 1 day before liver biopsy were evaluated.

Results: Sixty-nine (32.1%) and 43 (20.0%) patients had F2-4 and F3-4, respectively. LSM had higher diagnostic accuracy (area under receiver-operating characteristics curves [AUROC] 0.851 for F2-4, 0.940 for F3-4; Obuchowski index 0.937 ± 0.007) than all evaluated serum tests, while FM NAFLD was the most accurate serum test (AUROC 0.775 and 0.774; Obuchowski index 0.891 ± 0.013). FM VCTE had similar accuracy to LSM (AUROC 0.855 and 0.901; Obuchowski index 0.927 ± 0.009). LSM had excellent negative predictive values of 92.4% and 99.2% to exclude F2-4 and F3-4, but the positive predictive values (PPV) were only 71.4% and 61.0%, respectively. In patients with high LSM, the use of FM VCTE improved the PPV from 71.4% to 84.4% for F2-4 and from 61.0% to 88.9% for F3-4. Liver biopsy could be spared in around 50-65% of patients.

Conclusions: Liver stiffness measurement alone can confidently exclude significant and advanced fibrosis in NAFLD patients. Using FM VCTE in patients with high liver stiffness can increase the positive predictive value to rule in F2-4 and F3-4.

Keywords: FibroScan; NAFLD fibrosis score; cirrhosis; liver stiffness measurement; non-alcoholic steatohepatitis.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources