Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;14(3):331-338.
doi: 10.1016/j.hrthm.2016.12.008. Epub 2016 Dec 7.

Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness

Affiliations

Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness

Thomas Pambrun et al. Heart Rhythm. 2017 Mar.

Abstract

Background: For conventional ablation of paroxysmal atrial fibrillation (AF), an ablation catheter in conjunction with a circular mapping catheter (CMC) is typically used for pulmonary vein isolation (PVI).

Objective: The purpose of this study was to evaluate an approach for PVI with a single contact-force (CF) ablation catheter in terms of procedural reliability, outcomes, and cost-effectiveness.

Methods: One hundred consecutive patients with paroxysmal AF were included in the study. Fifty patients (study group) underwent a CF-guided single-catheter approach, whereby PVI was demonstrated when sequential pacing at 9 equidistant points within the lesion set (carina included) failed to capture the left atrium. For confirmation, PVI was verified with a CMC. In comparison, 50 patients (control group) underwent a conventional PVI ablation guided by a CMC.

Results: Procedure time (101 ± 17 minutes vs 107 ± 15 minutes, P = .11), ablation time (24.2 ± 7.1 minutes vs 22.6 ± 8.8 minutes, P = .37), fluoroscopy time (5.6 ± 2.2 minutes vs 8.3 ± 3.4 minutes, P = .09), and applied CF (17.8 ± 2.6 g vs 18 ± 2.8 g, P = .72) did not reach statistical difference between the study and control groups. CF-guided single-catheter ablation achieved successful PVI in 98% of the study group and a 31% reduction in cost. At 1-year follow-up, sinus rhythm maintenance rate was similar in both groups (86% vs 84%, P = .78).

Conclusion: In paroxysmal AF, a CF-guided single-catheter technique is an effective method for PVI, yielding substantial cost savings and clinical results similar to a conventional approach.

Keywords: Antral exit block; Atrial fibrillation; Catheter ablation; Contact-force sensing; Radiofrequency ablation.

PubMed Disclaimer

Comment in

MeSH terms

LinkOut - more resources