Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2017 May;151(5):1106-1113.
doi: 10.1016/j.chest.2016.11.035. Epub 2016 Dec 7.

The Power of Flash Mob Research: Conducting a Nationwide Observational Clinical Study on Capillary Refill Time in a Single Day

Collaborators, Affiliations
Observational Study

The Power of Flash Mob Research: Conducting a Nationwide Observational Clinical Study on Capillary Refill Time in a Single Day

Jelmer Alsma et al. Chest. 2017 May.

Abstract

Background: Capillary refill time (CRT) is a clinical test used to evaluate the circulatory status of patients; various methods are available to assess CRT. Conventional clinical research often demands large numbers of patients, making it costly, labor-intensive, and time-consuming. We studied the interobserver agreement on CRT in a nationwide study by using a novel method of research called flash mob research (FMR).

Methods: Physicians in the Netherlands were recruited by using word-of-mouth referrals, conventional media, and social media to participate in a nationwide, single-day, "nine-to-five," multicenter, cross-sectional, observational study to evaluate CRT. Patients aged ≥ 18 years presenting to the ED or who were hospitalized were eligible for inclusion. CRT was measured independently (by two investigators) at the patient's sternum and distal phalanx after application of pressure for 5 s (5s) and 15 s (15s).

Results: On October 29, 2014, a total of 458 investigators in 38 Dutch hospitals enrolled 1,734 patients. The mean CRT measured at the distal phalanx were 2.3 s (5s, SD 1.1) and 2.4 s (15s, SD 1.3). The mean CRT measured at the sternum was 2.6 s (5s, SD 1.1) and 2.7 s (15s, SD 1.1). Interobserver agreement was higher for the distal phalanx (κ value, 0.40) than for the sternum (κ value, 0.30).

Conclusions: Interobserver agreement on CRT is, at best, moderate. CRT measured at the distal phalanx yielded higher interobserver agreement compared with sternal CRT measurements. FMR proved a valuable instrument to investigate a relatively simple clinical question in an inexpensive, quick, and reliable manner.

Keywords: biomedical research; capillary refill time; data collection; physiology.