Comparison of multiple fluid status assessment methods in patients on chronic hemodialysis
- PMID: 27943170
- DOI: 10.1007/s11255-016-1473-y
Comparison of multiple fluid status assessment methods in patients on chronic hemodialysis
Abstract
Purpose: Control of hydration status is an important constituent of adequate and efficient hemodialysis (HD) treatment. Nevertheless, there are no precise clinical indices for early recognition of small changes in fluid status of patients undergoing chronic hemodialysis therapy. This study aimed to evaluate and compare the widely used and reliable method of indexed inferior vena cava diameter (IVCDi) with established and more recently available techniques (bioelectrical impedance analysis [BIA], continuous blood volume monitoring [Crit-line], and the B-line score [BLS] with lung ultrasonography) for estimating the hydration status of patients on HD.
Methods: Fifty-three patients undergoing chronic HD thrice weekly were included in the study. Evaluation of hydration status methods (IVCDi, BLS, BIA, and Crit-line) was performed thrice weekly before and after HD. Receiver operating characteristic curve analysis was performed to evaluate the discriminative power of (methods) the BLS, BIA, and Crit-line for predicting over- and underhydration of patients, as determined by the reference method, IVCDi.
Results: BLS showed the most promising results in predicting overhydration, as determined by IVCDi, compared with BIA and Crit-line and presented a sensitivity of 77% and specificity of 74%. The accuracy of the BLS was higher than that of BIA (0.81 vs. 0.71, p = 0.032) and Crit-line (0.61, p = 0.001). BLS also showed more promising results in predicting underhydration, as determined by IVCDi, than BIA and Crit-line and presented a sensitivity of 78% and a specificity of 73%. The accuracy of the BLS was higher than that of BIA (0.83 vs. 0.76, p = 0.035) and Crit-line (0.50, p < 0.001).
Conclusions: The BLS is a useful and easily performed technique that has recently become available for accurate evaluation of dry weight and fluid status in patients with end-stage renal disease undergoing chronic HD. This method might help recognize asymptomatic lung congestion in these patients.
Keywords: Bioelectrical impedance analysis (BIA); Crit-line; Dry weight; Fluid assessment; Hemodialysis patient; Indexed inferior vena cava diameter (IVCDi); Ultrasound lung comets/B-line score (BLS).
Similar articles
-
Diameter of inferior caval vein (VCD) and bioelectrical impedance analysis (BIA) for the analysis of hydration status in patients on hemodialysis.Clin Nephrol. 1998 Jul;50(1):38-43. Clin Nephrol. 1998. PMID: 9710345
-
Evaluation of volume overload by bioelectrical impedance analysis, NT-proBNP and inferior vena cava diameter in patients with stage 3&4 and 5 chronic kidney disease.Ren Fail. 2014 May;36(4):495-501. doi: 10.3109/0886022X.2013.875815. Epub 2014 Jan 23. Ren Fail. 2014. PMID: 24456050
-
Plasma brain natriuretic peptide concentration on assessment of hydration status in hemodialysis patient.Am J Kidney Dis. 2003 Jun;41(6):1257-66. doi: 10.1016/s0272-6386(03)00358-5. Am J Kidney Dis. 2003. PMID: 12776279
-
Assessment of Hydration Status in Peritoneal Dialysis Patients: Validity, Prognostic Value, Strengths, and Limitations of Available Techniques.Am J Nephrol. 2020;51(8):589-612. doi: 10.1159/000509115. Epub 2020 Jul 27. Am J Nephrol. 2020. PMID: 32721969 Review.
-
Bioelectrical impedance analysis in dialysis patients.Miner Electrolyte Metab. 1999 Jul-Dec;25(4-6):400-6. doi: 10.1159/000057482. Miner Electrolyte Metab. 1999. PMID: 10681674 Review.
Cited by
-
Fundamentals and Applications of the Receiver Operating Characteristic Curve Analysis in the Research of Endothelial Dysfunction in Chronic Kidney Disease.Life (Basel). 2022 Sep 9;12(9):1402. doi: 10.3390/life12091402. Life (Basel). 2022. PMID: 36143439 Free PMC article. Review.
-
Multiple Laplacian Regularized RBF Neural Network for Assessing Dry Weight of Patients With End-Stage Renal Disease.Front Physiol. 2021 Dec 13;12:790086. doi: 10.3389/fphys.2021.790086. eCollection 2021. Front Physiol. 2021. PMID: 34966294 Free PMC article.
-
Use of Point-of-Care Ultrasound for Evaluation of Extravascular and Intravascular Fluid Status in Pediatric Patients Maintained on Chronic Hemodialysis.Blood Purif. 2022;51(4):321-327. doi: 10.1159/000517365. Epub 2021 Jul 14. Blood Purif. 2022. PMID: 34350878 Free PMC article.
-
Utility of the Venous Excess Ultrasound (VEXUS) score to track dynamic change in volume status in patients undergoing fluid removal during haemodialysis - the ACUVEX study.Ultrasound J. 2024 Mar 27;16(1):23. doi: 10.1186/s13089-024-00370-9. Ultrasound J. 2024. PMID: 38538806 Free PMC article.
-
Scanning more corresponds to more accuracy in hemodialysis patients: 28-zone protocol's superior findings from an observational study.J Ultrasound. 2025 Mar;28(1):89-99. doi: 10.1007/s40477-024-00964-y. Epub 2024 Oct 21. J Ultrasound. 2025. PMID: 39432062
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical