ICD-ON Registry for Perioperative Management of CIEDs: Most Require No Change

Affiliations
Observational Study

ICD-ON Registry for Perioperative Management of CIEDs: Most Require No Change

Janet Gifford et al. Pacing Clin Electrophysiol. 2017 Feb.

Abstract

Background: There is significant variability in the perioperative management of patients with cardiac implanted electronic devices (CIEDs) undergoing procedures requiring electrosurgery.

Methods: We performed a multicenter registry from February 2014 to August 2015 at three suburban Chicago hospitals. Patients with transvenous CIEDs undergoing procedures requiring electrosurgery were assigned to one of three groups: (1) reprogram, (2) magnet, or (3) no change. Subjects with implantable cardioverter defibrillators (ICDs) or those pacemaker dependent having surgical procedures within 6 inches of their CIED were assigned to the reprogram group, whereby ICD therapies were programmed off with asynchronous pacing if pacemaker dependent. Subjects with ICDs ≥ 6 inches from their surgical site but above the iliac crest were assigned to the magnet group. All others were in the no change group. We evaluated electromagnetic interference (EMI) and postoperative device reset based on surgical location.

Results: All patients (n = 331) had pectoral CIEDs with mean age 73 years, 65% male, ejection fraction 56% for pacemaker subjects, 35% for ICD subjects with 22% pacemaker dependent. Assignments were n = 52 (16%) reprogram group, n = 51 (15%) magnet group, and n = 228 (69%) no change. There was EMI in 45% of thoracic cases, 35% of head/neck, 15% of upper extremity, and 3% of abdominal cases above iliac crest. There was no EMI in procedures below the iliac crest. There were no inappropriate therapies or device reset.

Conclusion: Results of the ICD-ON protocol demonstrate safe and efficient management of patients with CIEDs based on electrosurgery location, with 69% requiring no reprogramming or magnet application.

Keywords: ICD, pacing, magnet, electrosurgery, EMI; defibrillation.