Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jun;103(6):1878-1885.
doi: 10.1016/j.athoracsur.2016.09.057. Epub 2016 Dec 16.

Aortic Remodeling After Endovascular Repair of Complicated Acute Type B Aortic Dissection

Affiliations

Aortic Remodeling After Endovascular Repair of Complicated Acute Type B Aortic Dissection

Bradley G Leshnower et al. Ann Thorac Surg. 2017 Jun.

Abstract

Background: Thoracic endovascular aortic repair (TEVAR) is the optimal therapy for complicated acute type B aortic dissection (aTBAD). This study examined clinical outcomes and aortic remodeling parameters after TEVAR for patients with complicated aTBAD.

Methods: From January 2012 to December 2015, 51 patients underwent TEVAR for complicated aTBAD. Preoperative and postoperative imaging studies were analyzed for sizes of the true lumen (TL) and false lumen (FL) and for the FL thrombosis status at five locations in the thoracic and abdominal aorta.

Results: In-hospital and 1-year mortality rates were 3.9% and 5.8%, respectively. The incidence of stroke and paraparesis were 3.9% and 5.8%, respectively. In DeBakey 3a patients, TEVAR resulted in complete FL thrombosis and/or obliteration in 73% of patients. In DeBakey 3b patients, TEVAR resulted in complete FL thrombosis and/or obliteration in 100% of patients in the proximal descending thoracic aorta and 78% in the midpoint of the descending thoracic aorta. The infrarenal FL remained patent in 78% of patients. TEVAR stabilized the size of the proximal descending thoracic aorta (pre-TEVAR 43 ± 9 mm vs post-TEVAR 39 ± 7 mm; p = 0.07). However, significant aortic expansion was observed in all other downstream aortic segments. TEVAR resulted in a significant expansion in the TL volume (pre-TEVAR 99 ± 51 cm3 vs post-TEVAR 185 ± 70 cm3; p < 0.01) and total aortic volume (pre-TEVAR 314 ± 97 cm3 vs post-TEVAR 391 ± 120 cm3; p = 0.02) while inhibiting expansion of FL volume (pre-TEVAR 215 ± 67 cm3 vs post-TEVAR 204 ± 79 cm3; p = 0.91).

Conclusions: TEVAR for complicated aTBAD results in low 30-day and 1-year mortality rates, with higher reintervention rates than observed with open operations. TEVAR is effective in thrombosing and stabilizing the size of the thoracic FL. The abdominal aortic FL remains patent and must be carefully scrutinized for long-term aneurysm formation.

PubMed Disclaimer

MeSH terms

LinkOut - more resources