Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses
- PMID: 28007103
- DOI: 10.1016/j.jcrs.2016.10.016
Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lenses
Abstract
Purpose: To compare the postoperative quality of vision between different bilateral placements of near segments of rotationally asymmetric refractive multifocal intraocular lenses (IOLs) and to determine how this affects visual performance.
Setting: Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom.
Design: Retrospective comparative case series.
Methods: The study enrolled consecutive patients having refractive lens exchange and implantation of rotationally asymmetric multifocal IOLs. Group 1 received bilateral SBL-3 IOLs and Group 2 received bilateral Lentis Mplus LS-312 MF30 IOLs, with the near segments placed inferonasally in each group. Group 3 received a Lentis Mplus LS-312 MF20 IOL in the dominant eye with the near segment positioned superotemporal and a Lenstec SBL-3 IOL positioned inferonasally in the fellow eye. Binocular uncorrected (UDVA) and corrected distance visual acuities, binocular uncorrected near (UNVA) and intermediate (UIVA) visual acuities, binocular distance-corrected near and intermediate visual acuities, and quality of vision were evaluated over 3 months postoperatively.
Results: The study enrolled 180 patients (360 eyes). There was no significant difference between the groups in binocular UDVA, UIVA, and UNVA; however, there was a significant difference between the groups in quality of vision (P ≤ .001). Group 3 had significantly better overall quality of vision.
Conclusion: When implanting rotationally asymmetric multifocal IOLs, a combination of superotemporal placement of the near segment (+2.00 diopter [D] addition [add]) in the dominant eye with inferonasal placement of the near segment (+3.00 D add) in the fellow eye yielded consistent, high overall quality of vision and uncorrected visual acuity.
Financial disclosure: None of the authors has a financial or proprietary interest in any material or method mentioned.
Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses.J Cataract Refract Surg. 2017 Aug;43(8):1020-1026. doi: 10.1016/j.jcrs.2017.05.039. J Cataract Refract Surg. 2017. PMID: 28917400
-
Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision.J Cataract Refract Surg. 2015 May;41(5):945-55. doi: 10.1016/j.jcrs.2014.07.045. J Cataract Refract Surg. 2015. PMID: 26049829
-
Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.Ophthalmology. 2012 Mar;119(3):555-63. doi: 10.1016/j.ophtha.2011.08.036. Epub 2012 Jan 3. Ophthalmology. 2012. PMID: 22218147
-
[Multifocal intraocular lenses--an assessment of current status].Klin Monbl Augenheilkd. 1993 Jul;203(1):19-33. doi: 10.1055/s-2008-1045645. Klin Monbl Augenheilkd. 1993. PMID: 8411889 Review. German.
-
Comparison of postoperative visual performance between bifocal and trifocal intraocular Lens based on randomized controlled trails: a meta-analysis.BMC Ophthalmol. 2019 Mar 14;19(1):78. doi: 10.1186/s12886-019-1078-1. BMC Ophthalmol. 2019. PMID: 30871503 Free PMC article.
Cited by
-
Secondary positioning of rotationally asymmetric refractive multifocal intraocular lens in a patient with glaucoma: A case report.World J Clin Cases. 2022 Jul 16;10(20):7013-7019. doi: 10.12998/wjcc.v10.i20.7013. World J Clin Cases. 2022. PMID: 36051137 Free PMC article.
-
A Retrospective Comparative Performance Analysis of Multifocal Eyecryl Actv IOL and the World's First Progressive Polyfocal Autofocus Pro IOL.Clin Ophthalmol. 2025 Apr 28;19:1387-1399. doi: 10.2147/OPTH.S521607. eCollection 2025. Clin Ophthalmol. 2025. PMID: 40321165 Free PMC article.
-
Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.Int J Ophthalmol. 2017 Nov 18;10(11):1728-1733. doi: 10.18240/ijo.2017.11.15. eCollection 2017. Int J Ophthalmol. 2017. PMID: 29181318 Free PMC article.
-
Correction of presbyopia: An integrated update for the practical surgeon.Taiwan J Ophthalmol. 2018 Jul-Sep;8(3):121-140. doi: 10.4103/tjo.tjo_53_18. Taiwan J Ophthalmol. 2018. PMID: 30294526 Free PMC article. Review.
-
Visual and patient reported outcomes provided by a refractive multifocal intraocular lens based on continuous transitional focus.Eye Vis (Lond). 2024 Oct 14;11(1):41. doi: 10.1186/s40662-024-00408-y. Eye Vis (Lond). 2024. PMID: 39402644 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources