Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Feb 20:135:67-74.
doi: 10.1016/j.jpba.2016.12.007. Epub 2016 Dec 15.

A sensitive LC-MS/MS method for analysis of pericyazine in presence of 7-hydroxypericyazine and pericyazine sulphoxide in human plasma and its application to a comparative bioequivalence study in Chinese healthy volunteers

Affiliations
Randomized Controlled Trial

A sensitive LC-MS/MS method for analysis of pericyazine in presence of 7-hydroxypericyazine and pericyazine sulphoxide in human plasma and its application to a comparative bioequivalence study in Chinese healthy volunteers

Hua Lin Cai et al. J Pharm Biomed Anal. .

Abstract

A robust and highly sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of pericyazine in human plasma. The plasma sample was alkalized with sodium hydroxide solution and handled by liquid-liquid extraction with ethyl acetate after adding perphenazine as an internal standard (IS). The analytes were separated on an Ultimate™ AQ-C18 analytical column at 40°C, with a gradient elution consisting of A (aqueous phase: 5mM ammonium acetate buffer solution containing 0.1% formic acid) and B (organic phase: acetonitrile) at a flow rate of 0.350mL/min. The detection was conducted on an API 4000 tandem mass spectrometer coupled with electrospray ionization (ESI) source in positive ion mode. The multiple reaction monitoring (MRM) transitions, m/z 366.5>142.4 for pericyazine, m/z 382.5>142.4 for its 7-hydroxy and sulphoxide metabolites and m/z 404.3>171.3 for IS were chosen to achieve high selectivity in the simultaneous analyses. The method exhibited great improvement in sensitivity (LLOQ of 0.021ng/mL) and good linearity over the concentration range of 0.021-9.90ng/mL. The intra- and inter-day precision, accuracy, and stability results were within the acceptable limits and no matrix effect was observed. This method was successfully applied in a bioequivalence study to evaluate the pharmacokinetics in 20 healthy male Chinese volunteers. Additional exploratory analyses of 7-hydroxy and sulphoxide metabolites of pericyazine in the same samples suggest that the unchanged drug is predominant in the plasma and suitable for the bioequivalence comparison after a single oral administration of 10mg pericyazine.

Keywords: 7-Hydroxypericyazine; Bioequivalence; LC–MS/MS; Pericyazine; Pericyazine sulphoxide.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources