Measurement of the Intertablet Coating Uniformity of a Pharmaceutical Pan Coating Process With Combined Terahertz and Optical Coherence Tomography In-Line Sensing
- PMID: 28017653
- DOI: 10.1016/j.xphs.2016.12.012
Measurement of the Intertablet Coating Uniformity of a Pharmaceutical Pan Coating Process With Combined Terahertz and Optical Coherence Tomography In-Line Sensing
Abstract
We present in-line coating thickness measurements acquired simultaneously using 2 independent sensing modalities: terahertz pulsed imaging (TPI) and optical coherence tomography (OCT). Both techniques are sufficiently fast to resolve the coating thickness of individual pharmaceutical tablets in situ during the film coating operation, and both techniques are direct structural imaging techniques that do not require multivariate calibration. The TPI sensor is suitable to measure coatings greater than 50 μm and can penetrate through thick coatings even in the presence of pigments over a wide range of excipients. Due to the long wavelength, terahertz radiation is not affected by scattering from dust within the coater. In contrast, OCT can resolve coating layers as thin as 20 μm and is capable of measuring the intratablet coating uniformity and the intertablet coating thickness distribution within the coating pan. However, the OCT technique is less robust when it comes to the compatibility with excipients, dust, and potentially the maximum coating thickness that can be resolved. Using a custom-built laboratory scale coating unit, the coating thickness measurements were acquired independently by the TPI and OCT sensors throughout a film coating operation. Results of the in-line TPI and OCT measurements were compared against one another and validated with off-line TPI and weight gain measurements. Compared with other process analytical technology sensors, such as near-infrared and Raman spectroscopy, the TPI and OCT sensors can resolve the intertablet thickness distribution based on sampling a significant fraction of the tablet populations in the process. By combining 2 complementary sensing modalities, it was possible to seamlessly monitor the coating process over the range of film thickness from 20 μm to greater than 250 μm.
Keywords: coating thickness; coating uniformity; optical coherence tomography; pharmaceutical film coating; terahertz pulsed imaging; terahertz sensing.
Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Quantifying Pharmaceutical Film Coating with Optical Coherence Tomography and Terahertz Pulsed Imaging: An Evaluation.J Pharm Sci. 2015 Oct;104(10):3377-85. doi: 10.1002/jps.24535. Epub 2015 Jun 17. J Pharm Sci. 2015. PMID: 26284354 Free PMC article.
-
Terahertz pulsed imaging and near infrared imaging to monitor the coating process of pharmaceutical tablets.Int J Pharm. 2009 Mar 31;370(1-2):8-16. doi: 10.1016/j.ijpharm.2008.11.011. Epub 2008 Nov 25. Int J Pharm. 2009. PMID: 19084585
-
At-line validation of optical coherence tomography as in-line/at-line coating thickness measurement method.Int J Pharm. 2019 Dec 15;572:118766. doi: 10.1016/j.ijpharm.2019.118766. Epub 2019 Nov 6. Int J Pharm. 2019. PMID: 31705973
-
Terahertz pulsed imaging as an advanced characterisation tool for film coatings--a review.Int J Pharm. 2013 Dec 5;457(2):510-20. doi: 10.1016/j.ijpharm.2013.03.053. Epub 2013 Apr 6. Int J Pharm. 2013. PMID: 23570960 Review.
-
Application of terahertz pulsed imaging to analyse film coating characteristics of sustained-release coated pellets.Int J Pharm. 2013 Dec 5;457(2):521-6. doi: 10.1016/j.ijpharm.2013.05.039. Epub 2013 May 27. Int J Pharm. 2013. PMID: 23721891 Review.
Cited by
-
Raman Spectroscopy as a PAT-Tool for Film-Coating Processes: In-Line Predictions Using one PLS Model for Different Cores.Pharmaceutics. 2020 Aug 23;12(9):796. doi: 10.3390/pharmaceutics12090796. Pharmaceutics. 2020. PMID: 32842494 Free PMC article.
-
Multilayer Thickness Measurements below the Rayleigh Limit Using FMCW Millimeter and Terahertz Waves.Sensors (Basel). 2019 Sep 11;19(18):3910. doi: 10.3390/s19183910. Sensors (Basel). 2019. PMID: 31514296 Free PMC article.
-
Deep convolutional neural networks: Outperforming established algorithms in the evaluation of industrial optical coherence tomography (OCT) images of pharmaceutical coatings.Int J Pharm X. 2020 Nov 11;2:100058. doi: 10.1016/j.ijpx.2020.100058. eCollection 2020 Dec. Int J Pharm X. 2020. PMID: 33294841 Free PMC article.
-
Characterization of enteric-coated erythromycin tablets by Raman mapping and its pharmaceutical evaluation.Front Chem. 2023 Oct 18;11:1270737. doi: 10.3389/fchem.2023.1270737. eCollection 2023. Front Chem. 2023. PMID: 37920414 Free PMC article.
-
Co-registered combined OCT and THz imaging to extract depth and refractive index of a tissue-equivalent test object.Biomed Opt Express. 2020 Feb 19;11(3):1417-1431. doi: 10.1364/BOE.378506. eCollection 2020 Mar 1. Biomed Opt Express. 2020. PMID: 32206419 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous