Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies
- PMID: 28029638
- PMCID: PMC5338580
- DOI: 10.5152/dir.2016.16173
Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies
Abstract
Purpose: We aimed to evaluate the diagnostic accuracy and safety of computed tomography (CT)-guided biopsy of pulmonary lesions with fine needle aspiration (FNA) using non-coaxial technique.
Methods: We analyzed 442 patients who underwent CT-guided lung biopsy with FNA and non-coaxial technique to determine the diagnostic outcomes, complication rates, and independent risk factors for diagnostic failure and pneumothorax.
Results: Diagnostic accuracy, sensitivity, and specificity were 97.6%, 97.3%, and 100%, respectively. Age and >35 mm lesion size were significant risk factors for diagnostic failure. The rates of pneumothorax and chest tube placement were 19% and 2.9%, respectively. Middle and lower lobe location, lesion to pleura distance >7.5 mm, and >45° needle trajectory angle were significant risk factors for pneumothorax.
Conclusion: CT-guided FNA of pulmonary lesions with non-coaxial technique is a safe and reliable method with a relatively low pneumothorax rate and an acceptably high diagnostic accuracy.
Conflict of interest statement
The authors declared no conflicts of interest.
Figures
References
-
- Tsukada H, Satou T, Iwashima A, Souma T. Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol. 2000;175:239–243. https://doi.org/10.2214/ajr.175.1.1750239. - DOI - PubMed
-
- Hiraki T, Mimura H, Gobara H, et al. CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest. 2009;136:1612–1617. https://doi.org/10.1378/chest.09-0370. - DOI - PubMed
-
- Arakawa H, Nakajima Y, Kurihara Y, Niimi H, Ishikawa T. CT-guided transthoracic needle biopsy: a comparison between automated biopsy gun and fine needle aspiration. Clin Radiol. 1996;51:503–506. https://doi.org/10.1016/S0009-9260(96)80191-7. - DOI - PubMed
-
- Takeshita J, Masago K, Kato R, et al. CT-guided fine-needle aspiration and core needle biopsies of pulmonary lesions: a single-center experience with 750 biopsies in Japan. AJR Am J Roentgenol. 2015;204:29–34. https://doi.org/10.2214/AJR.14.13151. - DOI - PubMed
-
- Yeow KM, Tsay PK, Cheung YC, Lui KW, Pan KT, Chou AS. Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol. 2003;14:581–588. https://doi.org/10.1097/01.RVI.0000071087.76348.C7. - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical