Randomized Controlled Trial
. 2017 Mar:209:139-144.
doi: 10.1016/j.jss.2016.10.010. Epub 2016 Oct 15.

Three-year results of a randomized study comparing self-gripping mesh with sutured mesh in open inguinal hernia repair

Affiliations
Randomized Controlled Trial

Three-year results of a randomized study comparing self-gripping mesh with sutured mesh in open inguinal hernia repair

Ceith Nikkolo et al. J Surg Res. 2017 Mar.

Abstract

Background: The primary aim of the present study was to evaluate whether usage of self-gripping mesh in open inguinal hernia repair, compared with standard Lichtenstein repair with sutured mesh, could result in a decreased rate of chronic pain. The secondary aim was to evaluate the rate of foreign body feeling, hernia recurrence, and risk factors for chronic pain development.

Methods: The patients were randomized into two study groups: the OLP group received Optilene LP mesh and the PPG group received self-gripping Parietex ProGrip mesh. Pain scores were measured on a visual analog scale. Foreign body feeling was registered as a yes-no question.

Results: A total of 75 patients in the OLP group and 70 patients in the PPG group were analyzed at 3-y follow-up. According to the primary endpoint, of the patients, 41.3% in the OLP group and 28.6% in the PPG group experienced pain during different activities at 3-y follow-up (P = 0.108). The risk ratio for the primary endpoint was 1.45, 95% confidence interval (CI): 0.91, 2.29 (P = 0.114). Analysis demonstrated an increased rate of chronic pain in patients with severe preoperative pain (odds ratio: 2.47; 95% CI: 1.08, 5.65; P = 0.032) and severe early postoperative pain (odds ratio: 4.29; 95% CI: 1.82, 10.10; P = 0.001). Overall, of the patients, 28% in the OLP group and 21.4% in the PPG group reported foreign body feeling at the operation site at 3-y follow-up (P = 0.360). There were two hernia recurrences in the OLP group and none in the PPG group (P = 0.168).

Conclusions: We failed to demonstrate the advantages of self-gripping mesh in terms of chronic pain and foreign body feeling. However, usage of self-gripping mesh does not increase hernia recurrence rate. Considering the higher price of self-gripping mesh, analysis of cost-effectiveness is needed to prove its advantage and to justify its usage. As severe early postoperative pain is a risk factor for chronic pain development, a very effective postoperative pain control strategy is important after inguinal hernioplasty to reduce the rate of chronic pain.

Keywords: Chronic pain; Foreign body feeling; Inguinal hernia; Lichtenstein hernioplasty; Self-gripping mesh.

PubMed Disclaimer

Publication types

LinkOut - more resources