Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Mar:175:159-168.
doi: 10.1016/j.ajo.2016.12.009. Epub 2016 Dec 26.

A Multicenter Prospective Cohort Study on Refractive Surgery in 15 011 Eyes

Affiliations
Randomized Controlled Trial

A Multicenter Prospective Cohort Study on Refractive Surgery in 15 011 Eyes

Kazutaka Kamiya et al. Am J Ophthalmol. 2017 Mar.

Abstract

Purpose: To assess the clinical outcomes of currently used refractive surgery procedures performed in 2015.

Design: Prospective, multicenter cohort study.

Methods: This prospective study included 15 011 eyes of 7622 consecutive patients who underwent laser in situ keratomileusis (LASIK), surface ablation, refractive lenticule extraction (ReLEx), or phakic intraocular lens (IOL) implantation at 42 major institutions. We determined the safety, efficacy, predictability, stability, and adverse events of these surgeries preoperatively and at 1 week and 1 and 3 months postoperatively.

Results: Mean logMAR corrected distance visual acuity 3 months after LASIK, surface ablation, ReLEx, posterior chamber phakic IOL, or iris-supported phakic IOL implantation was -0.18 ± 0.07, -0.16 ± 0.08, -0.17 ± 0.09, -0.21 ± 0.08, and -0.10 ± 0.12, respectively; the corresponding values for logMAR uncorrected distance visual acuity were -0.15 ± 0.11, -0.12 ± 0.12, -0.12 ± 0.13, -0.15 ± 0.12, and 0.01 ± 0.21, respectively. The percentages within ±1.0 diopter (D) of the attempted correction were 96%, 93%, 97%, 99%, and 84% after LASIK, surface ablation, ReLEx, posterior chamber phakic IOL, and iris-supported phakic IOL implantation, respectively. Refractive change from 1 week to 3 months was -0.08 ± 0.07, 0.21 ± 0.63, -0.04 ± 0.41, 0.01 ± 0.31, and 0.01 ± 0.46 D, respectively. No vision-threatening complications occurred during the observation period.

Conclusions: Although more prolonged follow-up is still necessary, currently used refractive surgery procedures have good safety and efficacy outcomes, yielding predictable and stable results. Contemporary LASIK, surface ablation, ReLEx, and phakic IOL implantation appear to be feasible options for the treatment of refractive errors.