Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome
- PMID: 28062070
- PMCID: PMC5322482
- DOI: 10.1016/j.envint.2016.11.026
Trends in the application of high-resolution mass spectrometry for human biomonitoring: An analytical primer to studying the environmental chemical space of the human exposome
Abstract
Global profiling of xenobiotics in human matrices in an untargeted mode is gaining attention for studying the environmental chemical space of the human exposome. Defined as the study of a comprehensive inclusion of environmental influences and associated biological responses, human exposome science is currently evolving out of the metabolomics science. In analogy to the latter, the development and applications of high resolution mass spectrometry (HRMS) has shown potential and promise to greatly expand our ability to capture the broad spectrum of environmental chemicals in exposome studies. HRMS can perform both untargeted and targeted analysis because of its capability of full- and/or tandem-mass spectrum acquisition at high mass accuracy with good sensitivity. The collected data from target, suspect and non-target screening can be used not only for the identification of environmental chemical contaminants in human matrices prospectively but also retrospectively. This review covers recent trends and advances in this field. We focus on advances and applications of HRMS in human biomonitoring studies, and data acquisition and mining. The acquired insights provide stepping stones to improve understanding of the human exposome by applying HRMS, and the challenges and prospects for future research.
Copyright © 2016 Elsevier Ltd. All rights reserved.
Conflict of interest statement
The authors have no conflicts of interest.
Figures
References
-
- ALECHAGA É, MOYANO E, GALCERAN MT. Wide-range screening of psychoactive substances by FIA–HRMS: identification strategies. Analytical and Bioanalytical Chemistry. 2015;407:4567–4580. - PubMed
-
- ALVAREZ-SEGURA T, TORRES-LAPASIÓ JR, ORTIZ-BOLSICO C, GARCÍA-ALVAREZ-COQUE MC. Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review. Analytica Chimica Acta - PubMed
-
- AMIRAV A, KESHET U, ALON T, FIALKOV AB. Open Probe fast GC–MS—Real time analysis with separation. International Journal of Mass Spectrometry. 2014;371:47–53. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources