Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 1989 Sep;32(9):1111-23.
doi: 10.1080/00140138908966878.

Work tolerance and subjective responses to wearing protective clothing and respirators during physical work

Clinical Trial

Work tolerance and subjective responses to wearing protective clothing and respirators during physical work

M K White et al. Ergonomics. 1989 Sep.

Abstract

This study examined work tolerance and subjective responses while performing two levels of work and wearing four types of protective ensembles. Nine males (mean age = 24.8 years, weight = 75.3 kg, VO2 max = 44.6 ml/kg min) each performed a series of eight experimental tests in random order, each lasting up to 180 min in duration. Work was performed on a motor-driven treadmill at a set walking speed and elevation which produced work intensities of either 30% or 60% of each subject's maximum aerobic capacity. Work/rest intervals were established based on anticipated SCBA refill requirements. Environmental temperature averaged 22.6 degrees C and average relative humidity was 55%. The four protective ensembles were: a control ensemble consisting of light work clothing (CONTROL); light work clothing with an open circuit self-contained breathing apparatus (SCBA); firefighter's turnout gear with SCBA (FF); and chemical protective clothing with SCBA (CHEM). Test duration (tolerance time) was determined by physiological responses reaching a predetermined indicator of high stress or by a 180-min limit. Physiological and subjective measurements obtained every 2.5 min included: heart rate, skin temperature, rectal temperature, and subjective ratings of perceived exertion, thermal sensation, and perspiration. The mean tolerance times were 155, 130, 26, and 73 min, respectively, for the CONTROL, SCBA, FF, and CHEM conditions during low intensity work; and 91, 23, 4, and 13 min, respectively, during high intensity work. Differences between ensemble and work intensity were significant. FF and CHEM heart rate responses did not reach a steady state, and rose rapidly compared to CONTROL and SCBA values. SCBA heart rates remained approximately 15 beats higher than the CONTROL ensemble during the tests. At the low work intensity, mean skin temperatures at the end of the test were 32.7, 33.1, 36.7, and 36.3 degrees C, while mean core temperatures were 37.6, 37.9, 37.9, and 38.5 degrees C, respectively. The subjective data indicated that, in general, subjects were able to perceive relative degrees of physiologic strain under laboratory conditions. Wearing protective clothing and respirators results in significant and potentially dangerous thermoregulatory and cardiovascular stress to the wearer even at low work intensities in a neutral environment. Physiologically and subjectively, firefighter's turnout gear (the heaviest ensemble) produced the most stress, followed by the CHEM, SCBA, and CONTROL protective ensembles.

PubMed Disclaimer

Publication types

LinkOut - more resources