. 2017 Apr 1;18(4):392-401.
doi: 10.1093/ehjci/jew223.

Assessment of global longitudinal strain at low-dose anthracycline-based chemotherapy, for the prediction of subsequent cardiotoxicity

Affiliations

Assessment of global longitudinal strain at low-dose anthracycline-based chemotherapy, for the prediction of subsequent cardiotoxicity

Clément Charbonnel et al. Eur Heart J Cardiovasc Imaging. .

Abstract

Aims: We sought to assess whether global longitudinal strain (GLS) measured early during treatment with anthracyclines (at a cumulative dose of 150 mg/m2) can predict subsequent alterations in left ventricular ejection fraction.

Methods and results: Eighty-six patients with Hodgkin's disease, non-Hodgkin's lymphoma, or acute leukaemia and receiving anthracyclines were prospectively included. Patients underwent complete echocardiography on four occasions: baseline (V1); after reaching a cumulative dose of 150 mg/m2 (V2); end of treatment (V3); and 1 year follow-up (V4). Six patients developed cardiotoxicity, defined as a decrease in left ventricular ejection fraction of >10 percentage points, to a value <53%, at V4. GLS measured at V1 and V2 was significantly lower in the cardiotoxicity group vs. the controls (P = 0.042 and P = 0.01, respectively). Compared with GLS at V1, GLS obtained at V2 provided incremental predictive information and appeared to be the strongest predictor of cardiotoxicity (area under the receiver-operating-characteristic curve, 0.82). At a threshold of -17.45% for GLS measured at V2, the sensitivity and specificity of detecting cardiotoxicity were 67% (95% confidence interval 33-100) and 97% (95% confidence interval 94-100), respectively.

Conclusion: GLS greater than -17.45%, obtained after 150 mg/m2 of anthracycline therapy, is an independent predictor of future anthracycline-induced cardiotoxicity. These findings should encourage physicians to perform echocardiography earlier during treatment with anthracyclines.

Keywords: anthracyclines; cardiotoxicity; echocardiography; left ventricular function; strain.

PubMed Disclaimer

Comment in

Publication types

MeSH terms