Comparative Study
. 2017 Dec 1;19(12):1994-2000.
doi: 10.1093/europace/euw367.

Procedural outcomes and long-term survival following trans-venous defibrillator lead extraction in patients with end-stage renal disease

Affiliations
Comparative Study

Procedural outcomes and long-term survival following trans-venous defibrillator lead extraction in patients with end-stage renal disease

Anand D Shah et al. Europace. .

Abstract

Aims: End-stage renal disease (ESRD) increases the risk of implantable cardioverter-defibrillator (ICD) infection. We sought to define outcomes of lead extraction in patients with ESRD.

Methods and results: Implantable cardioverter-defibrillator lead extractions at our institution from January 2006 to March 2014 were stratified by absence (Control-Ex, n = 465) or presence (ESRD-Ex, n = 43) of ESRD. Procedural outcomes and survival were determined by medical records review. Survival in the ESRD-Ex group was compared with a contemporaneous cohort with ESRD undergoing ICD lead implantation (ESRD-I, n = 127). Among extraction patients, those with ESRD were more likely to be extracted for infection (74.4% vs. 28.6%, P < 0.001). Extraction procedure success (Control-Ex: 97% vs. ESRD-Ex: 93%, P = 0.17) and procedural deaths (Control-Ex: 1.1% vs. ESRD-Ex: 2.3%, P = 0.413) were similar. Survival 1 year following extraction was worse in the ESRD-Ex group compared with the Control-Ex, with a survival rate of 65.6% vs. 92.6% (P < 0.001); these curves continued to diverge through year 3. One-year survival in the ESRD-Ex group was worse than among ESRD patients undergoing ICD implant (ESRD-I), but these curves converged and survival was similar by year 3.

Conclusions: Implantable cardioverter-defibrillator lead extraction can be performed safely and effectively in patients with ESRD. However, despite high rates of procedural success, long-term mortality following extraction in ESRD patients is substantial. Much of the long-term mortality risk appears to be accounted for by the presence of ESRD and an indication for an ICD.

Keywords: Dialysis; End stage renal disease; Implantable cardioverter-defibrillator; Lead extraction.