. 2017 Sep;58(9):1125-1131.
doi: 10.1177/0284185116684676. Epub 2017 Jan 9.

Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

Affiliations

Leg lengthening and femoral-offset reduction after total hip arthroplasty: where is the problem - stem or cup positioning?

Bariq Al-Amiry et al. Acta Radiol. 2017 Sep.

Abstract

Background Restoration of femoral offset (FO) and leg length is an important goal in total hip arthroplasty (THA) as it improves functional outcome. Purpose To analyze whether the problem of postoperative leg lengthening and FO reduction is related to the femoral stem or acetabular cup positioning or both. Material and Methods Between September 2010 and April 2013, 172 patients with unilateral primary osteoarthritis treated with THA were included. Postoperative leg-length discrepancy (LLD) and global FO (summation of cup and FO) were measured by two observers using a standardized protocol for evaluation of antero-posterior plain hip radiographs. Patients with postoperative leg lengthening ≥10 mm (n = 41) or with reduced global FO >5 mm (n = 58) were further studied by comparing the stem and cup length of the operated side with the contralateral side in the lengthening group, and by comparing the stem and cup offset of the operated side with the contralateral side in the FO reduction group. We evaluated also the inter-observer and intra-observer reliability of the radiological measurements. Results Both observers found that leg lengthening was related to the stem positioning while FO reduction was related to the positioning of both the femoral stem and acetabular cup. Both inter-observer reliability and intra-observer reproducibility were moderate to excellent (intra-class correlation co-efficient, ICC ≥0.69). Conclusion Post THA leg lengthening was mainly caused by improper femoral stem positioning while global FO reduction resulted from improper positioning of both the femoral stem and the acetabular cup.

Keywords: Hip arthroplasty; femoral offset; leg length discrepancy; plain radiographs; reliability.