Hemodynamic Support With a Microaxial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention
- PMID: 28073804
- DOI: 10.1161/CIRCRESAHA.116.309738
Hemodynamic Support With a Microaxial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention
Abstract
Rationale: Acute kidney injury (AKI) is common during high-risk percutaneous coronary intervention (PCI), particularly in those with severely reduced left ventricular ejection fraction. The impact of partial hemodynamic support with a microaxial percutaneous left ventricular assist device (pLVAD) on renal function after high-risk PCI remains unknown.
Objective: We tested the hypothesis that partial hemodynamic support with the Impella 2.5 microaxial pLVAD during high-risk PCI protected against AKI.
Methods and results: In this retrospective, single-center study, we analyzed data from 230 patients (115 consecutive pLVAD-supported and 115 unsupported matched-controls) undergoing high-risk PCI with ejection fraction ≤35%. The primary outcome was incidence of in-hospital AKI according to AKI network criteria. Logistic regression analysis determined the predictors of AKI. Overall, 5.2% (6) of pLVAD-supported patients versus 27.8% (32) of unsupported control patients developed AKI (P<0.001). Similarly, 0.9% (1) versus 6.1% (7) required postprocedural hemodialysis (P<0.05). Microaxial pLVAD support during high-risk PCI was independently associated with a significant reduction in AKI (adjusted odds ratio, 0.13; 95% confidence intervals, 0.09-0.31; P<0.001). Despite preexisting CKD or a lower ejection fraction, pLVAD support protection against AKI persisted (adjusted odds ratio, 0.63; 95% confidence intervals, 0.25-0.83; P=0.04 and adjusted odds ratio, 0.16; 95% confidence intervals, 0.12-0.28; P<0.001, respectively).
Conclusions: Impella 2.5 (pLVAD) support protected against AKI during high-risk PCI. This renal protective effect persisted despite the presence of underlying CKD and decreasing ejection fraction.
Keywords: acute kidney injury; hemodynamic support; left ventricular dysfunction; percutaneous coronary intervention; ventricular assist device.
© 2017 American Heart Association, Inc.
Comment in
-
Letter by Naranjo et al Regarding Article, "Hemodynamic Support With a Micro-Axial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention".Circ Res. 2017 May 26;120(11):e51. doi: 10.1161/CIRCRESAHA.117.311090. Circ Res. 2017. PMID: 28546363 No abstract available.
-
Response by Flaherty to Letter Regarding Article, "Hemodynamic Support With a Micro-Axial Percutaneous Left Ventricular Assist Device (Impella) Protects Against Acute Kidney Injury in Patients Undergoing High-Risk Percutaneous Coronary Intervention".Circ Res. 2017 May 26;120(11):e52-e53. doi: 10.1161/CIRCRESAHA.117.311107. Circ Res. 2017. PMID: 28546364 No abstract available.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous