Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;63(3):761-769.
doi: 10.1373/clinchem.2016.265512. Epub 2017 Jan 18.

Quantification of BK Virus Standards by Quantitative Real-Time PCR and Droplet Digital PCR Is Confounded by Multiple Virus Populations in the WHO BKV International Standard

Affiliations

Quantification of BK Virus Standards by Quantitative Real-Time PCR and Droplet Digital PCR Is Confounded by Multiple Virus Populations in the WHO BKV International Standard

Allen C Bateman et al. Clin Chem. 2017 Mar.

Abstract

Background: The WHO recently released a BK virus (BKV) international standard. This study evaluated the WHO international standard and commercially available BKV standards by quantitative real-time PCR (qPCR) and droplet digital PCR (ddPCR).

Methods: WHO, Exact Diagnostics, Acrometrix, and Zeptometrix BKV standards were tested by qPCR and ddPCR. Two preparations of NIST BKV clones were also tested. Nucleic acid was extracted with the Roche MP96 and MPLC, followed by quantification in duplicate. To resolve discrepancies, we sequenced the WHO and NIST materials.

Results: Manufacturers' expected copies/mL were close to WHO IU/mL: linear regression of qPCR data revealed 1.12 Exact copies/IU, 0.76 Acrometrix copies/IU, and 0.70 Zeptometrix copies/IU. For ddPCR, similar concentrations were measured when either the VP1 region or the T region was targeted, and concentrations were almost 2-fold higher when both regions were targeted simultaneously. ddPCR results for the VP1 and T regions were similar for all commercial standards, but targeting the T region of the WHO standard led to a 4-fold lower result than the VP1 region. Next-generation sequencing revealed no primer or probe mismatches. However, large differences in coverage across the WHO standard and junctional reads were observed, indicating subpopulations of the WHO standard with deletions in the T region.

Conclusions: BKV standards showed concordance among providers, but the WHO standard contains subpopulations of viruses with various deletions in the T region. PCR results will vary depending on which region of the WHO standard is targeted.

PubMed Disclaimer

LinkOut - more resources