Application of distal radius-positioned hinged external fixator in complete open release for severe elbow stiffness
- PMID: 28104095
- DOI: 10.1016/j.jse.2016.09.019
Application of distal radius-positioned hinged external fixator in complete open release for severe elbow stiffness
Abstract
Background: Radical release for severe stiff elbows may lead to instability. Hinged external fixation is used to treat unstable elbows. We hypothesized that extensive open release combined with a distal radius-positioned hinged external fixator would have good performance and low complications rate in treating severe elbow stiffness. Thus, the efficacy and security of this technique were assessed in this study.
Methods: We retrospectively reviewed 38 post-traumatic elbows with severe stiffness that underwent arthrolysis between February 2011 and February 2014. All patients were assessed as having elbow instability after complete arthrolysis. Ligament repair was combined with implantation of a hinged external fixator (fixed to the humerus and distal radius) to maintain elbow stability. Flexion arc, forearm rotation, Mayo Elbow Performance Score, elbow stability, and radiographs were evaluated preoperatively and postoperatively, and complications were documented.
Results: Mean follow-up was 31 months. Significant improvement was noted in flexion-extension arc (from 27° to 126°), forearm rotation (from 148° to 153°), and mean Mayo Elbow Performance Score (from 68 points to 96 points). Mean pronation arc decreased from 66° preoperatively to 6° at 1.5 months of follow-up and showed a transient reduction during first 6 months postoperatively. Pin-related infection occurred in 2 patients, which was cured with conservative treatment. Two patients had moderate instability after removal of the fixator and regained stability at the 12-month follow-up. At the last follow-up, complications included ulnar nerve paralysis in 3, recurrence of heterotopic ossification in 1, and moderate pain in 1.
Conclusions: Complete open release combined with a distal radius-positioned hinged external fixator is an effective treatment for severe stiff elbows. This technique had a low complication rate.
Keywords: Elbow stiffness; arthrolysis; distal radius; hinged external fixation; instability; ligament.
Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Stability of severely stiff elbows after complete open release: treatment by ligament repair with suture anchors and hinged external fixator.J Shoulder Elbow Surg. 2014 Oct;23(10):1537-44. doi: 10.1016/j.jse.2014.03.013. Epub 2014 Jun 11. J Shoulder Elbow Surg. 2014. PMID: 24927881
-
[Treatment of elbow joint stiffness by open release combined with distal radius fixation hinged external fixation].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018 Feb 15;32(2):134-138. doi: 10.7507/1002-1892.201705102. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2018. PMID: 29806400 Free PMC article. Chinese.
-
[Hinged external fixation in orthopaedic and trauma surgery of the elbow].Acta Chir Orthop Traumatol Cech. 2013;80(6):391-5. Acta Chir Orthop Traumatol Cech. 2013. PMID: 24750966 Czech.
-
[External fixator of the elbow].Oper Orthop Traumatol. 2020 Oct;32(5):387-395. doi: 10.1007/s00064-020-00676-6. Epub 2020 Sep 21. Oper Orthop Traumatol. 2020. PMID: 32959082 Review. German.
-
Hinged elbow external fixators: indications and uses.J Am Acad Orthop Surg. 2005 Dec;13(8):503-14. doi: 10.5435/00124635-200512000-00003. J Am Acad Orthop Surg. 2005. PMID: 16330512 Review.
Cited by
-
Terrible triad injury of the elbow joint treated with total elbow arthroplasty: a case report.JSES Rev Rep Tech. 2023 Oct 1;4(1):113-117. doi: 10.1016/j.xrrt.2023.09.002. eCollection 2024 Feb. JSES Rev Rep Tech. 2023. PMID: 38323216 Free PMC article. No abstract available.
-
Open elbow arthrolysis with hinged external fixation for postburn elbow stiffness: a case series with an averaged 4-year follow-up.J Orthop Surg Res. 2025 Aug 12;20(1):760. doi: 10.1186/s13018-025-06155-7. J Orthop Surg Res. 2025. PMID: 40796846 Free PMC article.
-
The stiff elbow: Current concepts.Orthop Rev (Pavia). 2020 Jun 25;12(Suppl 1):8661. doi: 10.4081/or.2020.8661. eCollection 2020 Jun 29. Orthop Rev (Pavia). 2020. PMID: 32913596 Free PMC article.
-
An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint.Biomed Res Int. 2020 Nov 25;2020:3056395. doi: 10.1155/2020/3056395. eCollection 2020. Biomed Res Int. 2020. PMID: 33294437 Free PMC article.
-
What Range of Motion and Functional Results Can Be Expected After Open Arthrolysis with Hinged External Fixation For Severe Posttraumatic Elbow Stiffness?Clin Orthop Relat Res. 2019 Oct;477(10):2319-2328. doi: 10.1097/CORR.0000000000000726. Clin Orthop Relat Res. 2019. PMID: 31107330 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources