Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;28(3):983-990.
doi: 10.1007/s00198-016-3804-3. Epub 2017 Jan 20.

Opportunistic screening for osteoporosis by routine CT in Southern Europe

Affiliations

Opportunistic screening for osteoporosis by routine CT in Southern Europe

Elena Alacreu et al. Osteoporos Int. 2017 Mar.

Abstract

Feasibility evaluation of early detection of osteoporosis in oncologic patients by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed for other clinical indications, by using dual-energy X-ray absorptiometry (DXA) as reference. Abdominal CT images can identify patients with osteoporosis BMD without additional radiation exposure or cost.

Introduction: The purpose of the study is to evaluate the feasibility of early detection of osteoporosis by bone mineral density (BMD) on abdominal computed tomography (CT) scans performed in oncologic patients, comparing calibrated and uncalibrated measurements by using dual-energy X-ray absorptiometry (DXA) as reference. We also performed an external validation of a threshold of 160 Hounsfield units (HU), proposed as highly sensitive.

Methods: Cohort comprised CT-DXA pairs within a 6-month period performed for any indication on 326 consecutive adults, aged 62.4 ± 12.38 years (mean ± standard deviation). CT attenuation of trabecular bone in HU was measured at the axial cross sections of L1, L2, L3, and L4 vertebrae. Vertebral compression fractures were assessed by sagittal reconstruction view. Diagnostic performance measures and the area under the receiver operator characteristic curve (AUC) for diagnosing osteoporosis were calculated.

Results: BMD values were statistical significantly lower at any vertebral level from L1 to L4 for patients with osteoporosis defined by DXA (p < 0.001). Calibrated and uncalibrated BMD values were significantly correlated (R 2 = 0.833, p < 0.01). An uncalibrated L1 CT attenuation threshold of 160 HU was more than 90 % sensitive, and a threshold of 73 HU was more than 90 % specific for distinguishing osteoporosis BMD. Fifty-nine percent of patients with vertebral compression fracture had non-osteoporotic DXA T-scores.

Conclusions: Abdominal CT images obtained for other reasons can identify patients with osteoporosis BMD without additional radiation exposure or cost. Uncalibrated values at L1 can detect more osteoporosis patients with spinal compression fractures than DXA in oncologic patients.

Keywords: Bone density; Computed tomography; External validation; Lumbar vertebrae; Osteoporosis; Screening; Spinal fractures.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Osteoporos Int. 2012 May;23(5):1623-9 - PubMed
    1. Acad Radiol. 2012 Oct;19(10 ):1273-82 - PubMed
    1. Osteoporos Int. 2012 Sep;23(9):2239-56 - PubMed
    1. J Bone Miner Res. 1998 Aug;13(8):1337-42 - PubMed
    1. Osteoporos Int. 1995;5(6):433-9 - PubMed

Publication types

MeSH terms

LinkOut - more resources