[Development of a new quantitative analysis for thallium myocardial SPECT images--quantitative STEREO-VIEW method and evaluation of its clinical usefulness]
- PMID: 2810903
[Development of a new quantitative analysis for thallium myocardial SPECT images--quantitative STEREO-VIEW method and evaluation of its clinical usefulness]
Abstract
We have developed a three-dimensional quantitative display method, Quantitative STEREO-VIEW method (STEREO-VIEW method), for analysis of thallium (Tl) myocardial SPECT images and have evaluated its clinical usefulness. SPECT data were obtained immediately and 4 hours after the exercise, and contour lines for outer edges of left ventricular (LV) myocardium were detected from 10 slices of short axial images in delayed scan. LV wall was divided into 510 segments by dividing each slice into 51 sectors and LV myocardium was three-dimensionally reconstructed. Mean Tl counts, %T1 uptake and washout rate (WR) of each segment were calculated and these values were represented such as infarcted area display, redistribution display and WR display on STEREO-VIEW. Furthermore, extent index (EI), severity index (SI) and intensity index (II) were defined to express the degree of perfusion abnormality using WR value of each segment. In the 25 patients with coronary revascularization, improving rate of these indices correlated well with that of double product significantly. STEREO-VIEW method resembled in the original shape of left ventricle of each patient, so STEREO-VIEW method has made it easier to discriminate the accurate extent of ischemic lesion. In addition, EI, SI and II using WR were good indices for coronary perfusion and these were thought to be useful on clinical study.
Similar articles
-
[Three-dimensional display and its quantification of exercise stress myocardial tomography using thallium-201].J Cardiol. 1992;22(2-3):307-18. J Cardiol. 1992. PMID: 1339789 Japanese.
-
[Ischemic heart disease evaluated by exercise stress thallium-201 myocardial scintigraphy: a comparison of SPECT and bull's eye display].J Cardiol. 1989 Sep;19(3):679-86. J Cardiol. 1989. PMID: 2641762 Japanese.
-
[Comparison of two-dimensional echocardiography and Tl-201 SPECT in the evaluation of ischemic heart disease].J Cardiol. 1990;20(3):563-70. J Cardiol. 1990. PMID: 2131346 Japanese.
-
Analysis of thallium-201 myocardial SPECT images using fuzzy set theory.Ann Nucl Med. 1988 Nov;2(2):63-71. doi: 10.1007/BF03164947. Ann Nucl Med. 1988. PMID: 3275110
-
[Usefulness and pitfalls in myocardial perfusion SPECT for detecting and assessing coronary artery disease].J Cardiol. 2000 Mar;35 Suppl 1:37-42. J Cardiol. 2000. PMID: 10834168 Review. Japanese.
Cited by
-
Availability and limitations of thallium-201 myocardial SPECT quantitative analysis: assessment as daily routine procedure for ischemic heart disease.Ann Nucl Med. 1991 Mar;5(1):11-8. doi: 10.1007/BF03164608. Ann Nucl Med. 1991. PMID: 1863518
MeSH terms
Substances
LinkOut - more resources
Full Text Sources