Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial
- PMID: 28109874
- DOI: 10.1016/j.jcin.2016.11.007
Comparison of Durable-Polymer Zotarolimus-Eluting and Biodegradable-Polymer Biolimus-Eluting Coronary Stents in Patients With Coronary Artery Disease: 3-Year Clinical Outcomes in the Randomized SORT OUT VI Trial
Abstract
Objectives: The authors sought to compare the safety and efficacy of the biocompatible durable-polymer zotarolimus-eluting stent with the biodegradable-polymer biolimus-eluting stent in unselected coronary patients.
Background: Biodegradable-polymer biolimus-eluting stents are superior to first-generation durable-polymer drug-eluting stents in long-term randomized all-comer trials. Long-term data comparing them to second-generation durable-polymer drug-eluting stents are lacking.
Methods: The study was a randomized, multicenter, all-comer, noninferiority trial in patients with chronic stable coronary artery disease or acute coronary syndromes and at least 1 coronary artery lesion requiring treatment with a drug-eluting stent. Endpoints included major adverse cardiac events (MACE), a composite of safety (cardiac death and myocardial infarction not clearly attributable to a non-target lesion) and efficacy (target lesion revascularization); the individual endpoints of MACE; all-cause mortality; any myocardial infarction; target vessel revascularization; and definite or probable stent thrombosis at 36 months.
Results: From March 2011 to August 2012, 2,999 patients were randomly assigned (1:1) to receive either the zotarolimus-eluting (1,502 patients) or the biolimus-eluting (1,497 patients) stent. At 3-year follow-up, MACE occurred in 128 (8.6%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 144 (9.6%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.36). Occurrence of cardiac death (2.7% vs. 3.4%), myocardial infarction not clearly attributable to a non-target lesion (2.7% vs. 2.5%), and target lesion revascularization (5.4% vs. 5.5%) did not differ significantly between the 2 groups. Definite very late stent thrombosis occurred in 6 (0.4%) patients assigned to the durable-polymer zotarolimus-eluting stent and in 10 (0.7%) assigned to the biodegradable-polymer biolimus-eluting stent (p = 0.33).
Conclusions: At 3-year follow-up, the durable-polymer zotarolimus-eluting stent and the biodegradable-polymer biolimus-eluting stent were similar in clinical outcome, with no significant difference in safety and efficacy outcomes, including stent thrombosis.
Trial registration: ClinicalTrials.gov NCT01956448.
Keywords: biolimus; drug-eluting; polymer; randomized clinical trial; stent; zotarolimus.
Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
What Do Noninferiority Trials Say About Coronary Stents?JACC Cardiovasc Interv. 2017 Feb 13;10(3):265-267. doi: 10.1016/j.jcin.2016.11.041. Epub 2017 Jan 18. JACC Cardiovasc Interv. 2017. PMID: 28109877 No abstract available.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
