Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;24(3):328-336.
doi: 10.1016/j.acra.2016.11.007. Epub 2017 Jan 16.

Computer-aided Diagnosis for Lung Cancer: Usefulness of Nodule Heterogeneity

Affiliations

Computer-aided Diagnosis for Lung Cancer: Usefulness of Nodule Heterogeneity

Mizuho Nishio et al. Acad Radiol. 2017 Mar.

Abstract

Rationale and objectives: To develop a computer-aided diagnosis system to differentiate between malignant and benign nodules.

Materials and methods: Seventy-three lung nodules revealed on 60 sets of computed tomography (CT) images were analyzed. Contrast-enhanced CT was performed in 46 CT examinations. The images were provided by the LUNGx Challenge, and the ground truth of the lung nodules was unavailable; a surrogate ground truth was, therefore, constructed by radiological evaluation. Our proposed method involved novel patch-based feature extraction using principal component analysis, image convolution, and pooling operations. This method was compared to three other systems for the extraction of nodule features: histogram of CT density, local binary pattern on three orthogonal planes, and three-dimensional random local binary pattern. The probabilistic outputs of the systems and surrogate ground truth were analyzed using receiver operating characteristic analysis and area under the curve. The LUNGx Challenge team also calculated the area under the curve of our proposed method based on the actual ground truth of their dataset.

Results: Based on the surrogate ground truth, the areas under the curve were as follows: histogram of CT density, 0.640; local binary pattern on three orthogonal planes, 0.688; three-dimensional random local binary pattern, 0.725; and the proposed method, 0.837. Based on the actual ground truth, the area under the curve of the proposed method was 0.81.

Conclusions: The proposed method could capture discriminative characteristics of lung nodules and was useful for the differentiation between malignant and benign nodules.

Keywords: CAD; CT; Computer-aided diagnosis; Lung cancer.

PubMed Disclaimer

Comment in

  • Letter to the Editor: Use of Publicly Available Image Resources.
    Armato SG 3rd, Drukker K, Li F, Hadjiiski L, Tourassi GD, Engelmann RM, Giger ML, Redmond G, Farahani K, Kirby JS, Petrick NA. Armato SG 3rd, et al. Acad Radiol. 2017 Jul;24(7):916-917. doi: 10.1016/j.acra.2017.03.015. Epub 2017 May 11. Acad Radiol. 2017. PMID: 28506513 No abstract available.
  • Response to the Letter from LUNGx Challenge.
    Nishio M. Nishio M. Acad Radiol. 2017 Jul;24(7):918. doi: 10.1016/j.acra.2017.04.003. Epub 2017 May 15. Acad Radiol. 2017. PMID: 28522151 No abstract available.