Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Apr;40(4):554-560.
doi: 10.2337/dc16-0684. Epub 2017 Jan 23.

Comparison of Insulin Glargine 300 Units/mL and 100 Units/mL in Adults With Type 1 Diabetes: Continuous Glucose Monitoring Profiles and Variability Using Morning or Evening Injections

Affiliations
Randomized Controlled Trial

Comparison of Insulin Glargine 300 Units/mL and 100 Units/mL in Adults With Type 1 Diabetes: Continuous Glucose Monitoring Profiles and Variability Using Morning or Evening Injections

Richard M Bergenstal et al. Diabetes Care. 2017 Apr.

Abstract

Objective: The objective of this study was to compare glucose control in participants with type 1 diabetes receiving insulin glargine 300 units/mL (Gla-300) or glargine 100 units/mL (Gla-100) in the morning or evening, in combination with mealtime insulin.

Research design and methods: In this 16-week, exploratory, open-label, parallel-group, two-period crossover study (clinicaltrials.gov identifier NCT01658579), 59 adults with type 1 diabetes were randomized (1:1:1:1) to once-daily Gla-300 or Gla-100 given in the morning or evening (with crossover in the injection schedule). The primary efficacy end point was the mean percentage of time in the target glucose range (80-140 mg/dL), as measured using continuous glucose monitoring (CGM), during the last 2 weeks of each 8-week period. Additional end points included other CGM glycemic control parameters, hypoglycemia (per self-monitored plasma glucose [SMPG]), and adverse events.

Results: The percentage of time within the target glucose range was comparable between the Gla-300 and Gla-100 groups. There was significantly less increase in CGM-based glucose during the last 4 h of the 24-h injection interval for Gla-300 compared with Gla-100 (least squares mean difference -14.7 mg/dL [95% CI -26.9 to -2.5]; P = 0.0192). Mean 24-h glucose curves for the Gla-300 group were smoother (lower glycemic excursions), irrespective of morning or evening injection. Four metrics of intrasubject interstitial glucose variability showed no difference between Gla-300 and Gla-100. Nocturnal confirmed (<54 mg/dL by SMPG) or severe hypoglycemia rate was lower for Gla-300 participants than for Gla-100 participants (4.0 vs. 9.0 events per participant-year; rate ratio 0.45 [95% CI 0.24-0.82]).

Conclusions: Less increase in CGM-based glucose levels in the last 4 h of the 24-h injection interval, smoother average 24-h glucose profiles irrespective of injection time, and reduced nocturnal hypoglycemia were observed with Gla-300 versus Gla-100.

PubMed Disclaimer

Publication types

Associated data