Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2017 Mar;110(3):179-187.
doi: 10.1016/j.acvd.2016.09.002. Epub 2017 Jan 20.

Radial versus femoral access for coronary angiography and intervention is associated with lower patient radiation exposure in high-radial-volume centres: Insights from the RAY'ACT-1 study

Affiliations
Free article
Observational Study

Radial versus femoral access for coronary angiography and intervention is associated with lower patient radiation exposure in high-radial-volume centres: Insights from the RAY'ACT-1 study

Jean-Louis Georges et al. Arch Cardiovasc Dis. 2017 Mar.
Free article

Abstract

Background: Literature suggests that radial access is associated with higher radiation doses than femoral access.

Aims: To compare patient radiation exposure during coronary angiography (CA) and percutaneous coronary intervention (PCI) with radial versus femoral access.

Methods: RAY'ACT is a nationwide, multicentre, French survey evaluating patient radiation in interventional cardiology. Variables of patient exposure from 21,675 CAs and 17,109 PCIs performed at 44 centres during 2010 were analysed retrospectively.

Results: Radial access was used in 71% of CAs and 69% of PCIs. Although median fluoroscopy times were longer for radial versus femoral access (CA, 3.8 vs 3.5minutes [P<0.001]; PCI, 10.4 vs 10.1minutes [P=0.001]), the Kerma-area product (KAP) was lower with radial access (CA, 26.8 vs 28.1Gy·cm2; PCI, 55.6 vs 59.4Gy·cm2; both P=0.001). Differences in KAP remained significant in the multivariable analysis (P<0.01), and in a propensity score-matched analysis (P=0.01). A significant interaction was found between KAP and the percentage of procedures with radial access by centre (P<0.001). KAP was higher by radial versus femoral access in low-radial-volume centres, and lower in high-radial-volume centres. Radiation protection techniques, such as the use of low frame rates (7.5 frame/s), were used more frequently in high-radial-volume radial centres.

Conclusions: In this multicentre study, radial access was associated with lower radiation doses to patient than femoral access in high-radial-volume centres. Provided that radioprotection methods are implemented, radial access could be associated with lower patient radiation exposure.

Keywords: Angioplastie coronaire; Coronarographie; Coronary angiography; Kerma-area product; Percutaneous coronary intervention; Produit dose-surface; Radial access; Radiation protection; Radioprotection; Voie radiale.

PubMed Disclaimer

MeSH terms

LinkOut - more resources