Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;58(2):290-295.
doi: 10.3349/ymj.2017.58.2.290.

Nobori-Biolimus-Eluting Stents versus Resolute Zotarolimus-Eluting Stents in Patients Undergoing Coronary Intervention: A Propensity Score Matching

Affiliations

Nobori-Biolimus-Eluting Stents versus Resolute Zotarolimus-Eluting Stents in Patients Undergoing Coronary Intervention: A Propensity Score Matching

Ayman Tantawy et al. Yonsei Med J. 2017 Mar.

Abstract

Purpose: To compare the 1-year outcomes of a durable polymer Zotarolimus-eluting stent (ZES) versus a biodegradable polymer Biolimus-eluting stent (BES) in patients undergoing percutaneous coronary intervention.

Materials and methods: A total of 2083 patients from 2 different registries, 1125 treated with BES in NOBORI registry and 858 received ZES in CONSTANT registry were included in this study. Clinical outcomes were compared with the use of propensity score matching (PSM). The primary endpoint was a composite of major adverse cardiovascular and cerebrovascular events (MACCEs) including cardiac death, myocardial infarction, clinically driven target lesion revascularization and stroke. Secondary end points were individual components of MACCEs as well as the incidence of stent thrombosis at 1-year follow-up.

Results: After PSM, 699 matched pairs of patients (n=1398) showed no significant difference between BES and ZES in the risk of composite MACCEs at 1 year (2.6% vs. 1.7%; p=0.36). Cardiac death was not statistically different between groups (0.7% vs. 0.4%, p=0.73). Target lesion revascularization rate was also similar between BES and ZES (1.1% vs. 0.7%, p=0.579). Non-Q wave myocardial infarction, as well as target-vessel revascularization rate, was similar between the two groups (0.14% for BES and 0.72% for ZES). Both stent types were excellent with no cases of stent thrombosis and rate of Q wave myocardial infarction reported during the follow-up period.

Conclusion: In this cohort of patients treated with BES or ZES, the rate of MACCEs at 1 year was low and significantly not different between both groups.

Keywords: Percutaneous coronary intervention; biolimus A9; drug-eluting stents; polymers; propensity score; zotarolimus.

PubMed Disclaimer

Conflict of interest statement

The authors have no financial conflicts of interest.

References

    1. Choi YJ, Kim JB, Cho SJ, Cho J, Sohn J, Cho SK, et al. Changes in the practice of coronary Rrvascularization between 2006 and 2010 in the Republic of Korea. Yonsei Med J. 2015;56:895–903. - PMC - PubMed
    1. Morice MC, Serruys PW, Sousa JE, Fajadet J, Ban Hayashi E, Perin M, et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med. 2002;346:1773–1780. - PubMed
    1. Moses JW, Leon MB, Popma JJ, Fitzgerald PJ, Holmes DR, O'Shaughnessy C, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med. 2003;349:1315–1323. - PubMed
    1. Stone GW, Ellis SG, Cox DA, Hermiller J, O'Shaughnessy C, Mann JT, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med. 2004;350:221–231. - PubMed
    1. Camenzind E, Steg PG, Wijns W. Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern. Circulation. 2007;115:1440–1455. - PubMed