Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jul;9(7):679-685.
doi: 10.1136/neurintsurg-2016-012946. Epub 2017 Jan 27.

Endovascular flow diversion for treatment of anterior communicating artery region cerebral aneurysms: a single-center cohort of 50 cases

Affiliations

Endovascular flow diversion for treatment of anterior communicating artery region cerebral aneurysms: a single-center cohort of 50 cases

Geoffrey P Colby et al. J Neurointerv Surg. 2017 Jul.

Abstract

Background: Flow diversion represents a novel but definitive treatment for recurrent and difficult-to-coil aneurysms of the anterior communicating artery (ACoA) region, of which reports are limited.

Objective: To determine the effectiveness of the Pipeline embolization device (PED) in treating aneurysms in the ACoA region.

Methods: We retrospectively reviewed an IRB-approved database of patients with an aneurysm at a single institution for patients with ACoA or A1-A2 aneurysms treated with PED. Data analyzed included demographics, aneurysm characteristics, procedural details, follow-up results, and outcomes.

Results: A total of 50 procedures were performed on 41 patients, including seven patients who underwent bilateral 'H-pipe' PED placement. The average age was 56 years and 46% of the patients were female. The average aneurysm size was 4.5 mm, and two large (>10 mm) aneurysms were treated. The vessel of origin was either the ACoA (26 aneurysms, 63%) or the A1-A2 junction (15 aneurysms, 37%). Eighteen patients (44%) had prior subarachnoid hemorrhage and 20 had previously been treated either with clipping (6 aneurysms, 15%) or coiling (14 aneurysms, 34%). Procedural success was achieved in 48/50 cases (96%) and two cases were aborted. Coils were deployed adjunctively in two cases (4%). Procedural outcomes included no deaths, one major ischemic stroke (2%), and two patients with intracranial hemorrhage (4%). Complete aneurysm occlusion was achieved in 81% of patients at 6 months and 85% of patients at last follow-up digital subtraction angiography.

Conclusions: The PED can be used safely and effectively in the treatment of aneurysms of the ACoA region. This represents a good alternative treatment option to microsurgical clipping and endovascular coiling.

Keywords: Aneurysm; Flow Diverter; Technique.

PubMed Disclaimer

Conflict of interest statement

Competing interests: AC is a consultant and proctor for Medtronic, Styker, and Microvention. GPC is a consultant for Medtronic and Microvention.

LinkOut - more resources