Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2017 Oct;61(5):582-590.
doi: 10.1111/1754-9485.12587. Epub 2017 Jan 31.

Systematic review and meta-analysis of the diagnostic accuracy of low-dose computed tomography of the kidneys, ureters and bladder for urolithiasis

Affiliations
Meta-Analysis

Systematic review and meta-analysis of the diagnostic accuracy of low-dose computed tomography of the kidneys, ureters and bladder for urolithiasis

Hao Xiang et al. J Med Imaging Radiat Oncol. 2017 Oct.

Abstract

Renal colic is a common clinical condition which is often investigated with a CT of the kidneys, ureters and bladder (CTKUB). Recent technological improvements have allowed a reduction in dose with the emergence of low-dose CTKUB (LD-CTKUB) techniques. The present meta-analysis aims to determine the diagnostic accuracy of LD-CTKUB in the diagnosis of clinically significant uroliths. A systematic review was performed using nine electronic databases from their dates of inception to May 2016. Inclusion criteria included studies reporting comparative outcomes using LD-CTKUB with a dose less than 3 millisieverts compared to an imaging gold standard or clinical and surgical evaluation. The primary endpoint was detection of a urolith ≥3 mm where specified and any urolith when size was unspecified. Twelve studies were identified according to selection criteria, involving 1250 patients. LD-CTKUB demonstrated a pooled sensitivity of 93.1% (95%CI 91.5-94.4), specificity of 96.6% (95%CI 95.1-97.7%), positive likelihood ratio of 19.9 (95%CI 12.7-31.2), negative likelihood ratio of 0.05 (95%CI 0.02-0.10) and AUC of 0.9877 in the detection of clinically significant uroliths. Although 86 alternative diagnoses were noted across seven studies, none assessed the accuracy of LD-CTKUB in their detection. The majority of newer studies report an average radiation dose from 1 to 1.5 millisieverts. This study demonstrates a high sensitivity, specificity and positive predictive value in the detection of uroliths, however, its accuracy in the detection of alternative diagnoses is unknown. Therefore, we recommend using LD-CTKUB when the pre-test probability of stone disease is significantly higher than the pre-test probability of alternative diagnoses, such as follow-up of known calculi. We suggest caution when the pre-test probability of alternative diagnoses is high, such as the initial presentation of renal colic.

Keywords: abdomen; physics; urinary tract imaging; uroradiology.

PubMed Disclaimer

MeSH terms