Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr;208(4):916-922.
doi: 10.2214/AJR.16.16576. Epub 2017 Jan 31.

Imaging-Concordant Benign MRI-Guided Vacuum-Assisted Breast Biopsy May Not Warrant MRI Follow-Up

Affiliations

Imaging-Concordant Benign MRI-Guided Vacuum-Assisted Breast Biopsy May Not Warrant MRI Follow-Up

Monica L Huang et al. AJR Am J Roentgenol. 2017 Apr.

Abstract

Objective: The follow-up of breast lesions with imaging-concordant benign histopathology results on MRI-guided vacuum-assisted biopsy (VAB) is not currently standardized. We determined the false omission rate of breast MRI-guided VAB with benign histopathology (negative results) to assess whether breast MRI follow-up is needed.

Materials and methods: The medical records of patients who underwent 9-gauge breast MRI-guided VAB during 2007-2012 were reviewed retrospectively. Lesions with imaging-concordant benign histopathology results from MRI-guided VAB and surgery or 2 years or more of imaging follow-up were included. The false omission rate (1 - negative predictive value; [number of false-negative results / number of negative results]) of MRI-guided VAB was calculated.

Results: One hundred sixty-nine lesions were included, and 135 had only imaging follow-up (mammography follow-up: range, 17-107 months [median, 52 months]; MRI follow-up: range, 5-95 months [median, 35 months]). Of the 135 lesions with only imaging follow-up, 48 had mammography only (range, 26-86 months; median, 52 months), and 87 had mammography (range, 17-107 months; median, 52 months) and MRI (range, 5-95 months; median, 35 months). Thirty-four lesions had surgical correlation, and there were no cases of imaging-surgical discordance. Four malignancies were later diagnosed in the same breast in which MRI-guided VAB had been performed. One (0.6%) malignancy was invasive ductal carcinoma at 1 cm from the MRI-guided VAB site; it was mammographically detected 24 months after MRI-guided VAB. The other three malignancies developed 4 cm or more from the site of MRI-guided VAB: one ductal carcinoma in situ (DCIS) detected on mammography 12 months after MRI-guided VAB, one DCIS detected on MRI 24 months after MRI-guided VAB, and one Paget disease lesion detected at physical examination 32 months after MRI-guided VAB.

Conclusion: Breast MRI-guided VAB has a low false omission rate. MRI follow-up of lesions with concordant benign MRI-guided VAB histopathology results may not be warranted.

Keywords: MRI-guided; benign; breast; imaging-concordant; vacuum-assisted breast biopsy.