Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar 10:1488:77-84.
doi: 10.1016/j.chroma.2017.01.075. Epub 2017 Jan 27.

Selective chromatographic separation of polycarbonate according to hydroxyl end-groups using a porous graphitic carbon column

Affiliations

Selective chromatographic separation of polycarbonate according to hydroxyl end-groups using a porous graphitic carbon column

N Apel et al. J Chromatogr A. .

Abstract

Porous graphitic carbon (PGC) has shown unique separation efficiency in liquid chromatography for a wide range of substance classes. In the characterization of polymers PGC has particularly been used for analysis of polyolefins. Its retention mechanisms differ dramatically from those of silica-based stationary phases and therefore allow interesting applications. Due to its unprecedented retention mechanisms PGC does not only promise good separation performance for polyolefins but also for more polar polymers such as Polycarbonate (PC). In this study, we determined the critical conditions of PC on PGC using CHCl3/dichlorobenzene (DCB) and CHCl3/trichlorobenzene (TCB) as eluents achieving separations according to hydroxyl end-groups, which was confirmed by MALDI-TOF-MS analysis. As the content of TCB at the critical point was lower compared to that of DCB, it was concluded that TCB is a stronger desorption promoting eluent than DCB for the present system. The temperature influence on the critical point was then investigated revealing that with increasing temperature the content of desorption promoting eluent has to be raised in order to achieve critical conditions. Furthermore, a peak shifting over time was observed using TCB as desorption promoting eluent, which was attributed to irreversibly adsorbed PC on the column material. However, when a flow cell-IR detector was applied monitoring the eluted samples, a recovery rate close to 100% was found.

Keywords: Liquid chromatography at critical conditions; Poly(bisphenol A)carbonate; Porous graphitic carbon.

PubMed Disclaimer