Multicenter Study
. 2017 Sep;70(9):699-705.
doi: 10.1016/j.rec.2016.12.040. Epub 2017 Jan 31.

Nonfluoroscopic Catheter Ablation. Results From a Prospective Multicenter Registry

[Article in English, Spanish]
Affiliations
Multicenter Study

Nonfluoroscopic Catheter Ablation. Results From a Prospective Multicenter Registry

[Article in English, Spanish]
Miguel Álvarez et al. Rev Esp Cardiol (Engl Ed). 2017 Sep.

Abstract

Introduction and objectives: Nonfluoroscopic catheter ablation is feasible in most procedures. The aim of our registry was to evaluate the safety and feasibility of a zero-fluoroscopic approach to catheter ablation in several Spanish centers.

Methods: Eleven centers prospectively included a minimum of 20 patients. Patients with an arrhythmic substrate deemed suitable by the operator for a zero-fluoroscopic approach throughout the procedure were recruited. Patients with intracardiac devices were not included. Attending electrophysiologists, fellows, and resident physicians participated in each procedure, as in usual care.

Results: The study included 247 patients. Ablation was performed in 235 patients (95.2%). In 2 patients, who were not included in the analysis, fluoroscopy was performed as the first-line treatment. The arrhythmic substrate was located in the right chambers in most of the procedures (231 of 233 [99.15%]). Fluoroscopy was used in 24 procedures (10.3%). Catheter ablation was successful in 96.4% of the procedures and severe complications occurred in 2 patients (0.85%). Two variables were related to the need for fluoroscopy: the performing center (minimum 0% vs maximum 30.3%; P=.001) and procedural failure (13% vs 2.4%; P<.05).

Conclusions: The Spanish multicenter registry reveals that a zero-fluoroscopic approach is feasible in most right-sided catheter ablation procedures. Randomized trials are necessary to confirm the safety of this approach. The need for fluoroscopy was related to procedural failure, with significant differences among performing centers.

Keywords: Ablación con catéter; Catheter ablation; Fluoroscopia; Fluoroscopy; Registro; Registry.