Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Oct;25(5):1621-1628.
doi: 10.1007/s12350-017-0789-z. Epub 2017 Feb 3.

Comparison between the summed difference score and myocardial blood flow measured by 13N-ammonia

Affiliations
Comparative Study

Comparison between the summed difference score and myocardial blood flow measured by 13N-ammonia

Raffaele Giubbini et al. J Nucl Cardiol. 2018 Oct.

Abstract

Background: Both the myocardial perfusion pattern and myocardial blood flow (MBF) are used to assess patients with suspected coronary artery disease (CAD). The aim of this study was to compare the perfusion pattern (using the summed difference score [SDS]) to MBF in a consecutive group of patients undergoing PET/CT with 13 N-ammonia (13NH3).

Methods: 47 consecutive patients, aged 65 ± 12 years (42 men) with known or suspected CAD, underwent vasodilator stress/rest PET/CT with 13NH3 for clinical indications. The SDS was determined by a commercially available software based on a 17-segment model. MBF was measured at rest and during hyperemia by dynamic acquisition and single-compartment model analysis. From the rest and stress MBF, the absolute difference (stress-rest) in myocardial blood flow defined as difference in myocardial blood flow (DMBF) was derived.

Results: There were no significant differences between patients with no ischemia (SDS ≤ 1) and those with ischemia (SDS > 1) in CFR (2.84 ± 0.73 vs 2.63 ± 0.89, P = NS) and DMBF (1.34 ± 0.45 vs 1.24 ± 0.53 mL·minute-1·g-1, P = NS). There were however significant regional differences (141 different vascular territories in 47 patients) between these two groups (CFR: 2.84 ± 0.95 vs 2.16 ± 0.57, P < .001 and DMBF: 1.39 ± 0.6 vs 0.87 ± 0.39, P < .0001). The correlation between regional CFR and regional DMBF with SDS was significant (y = 2.7145e-0.059x R = 0.358 and y = 1.2769e-0.119x R = 0.44) CONCLUSION: The SDS is the difference between two measurements (stress-rest) and it correlates better with regional DMBF, which is another measurement that reflects the difference between stress and rest. The correlation is better on regional than global basis.

Keywords: Coronary blood flow; Coronary flow reserve; Myocardial perfusion imaging: PET; N-13 ammonia.

PubMed Disclaimer

Comment in

References

    1. Circulation. 2008 Mar 11;117(10):1283-91 - PubMed
    1. J Nucl Cardiol. 2004 Mar-Apr;11(2):171-85 - PubMed
    1. J Nucl Cardiol. 2002 Mar-Apr;9(2):240-5 - PubMed
    1. Nucl Med Commun. 2016 Apr;37(4):412-21 - PubMed
    1. J Am Coll Cardiol. 2009 Jul 7;54(2):150-6 - PubMed

Publication types

LinkOut - more resources