Randomized Controlled Trial
. 2017 Jun;255(6):1073-1078.
doi: 10.1007/s00417-017-3598-9. Epub 2017 Feb 4.

Macular hole closure patterns associated with different internal limiting membrane flap techniques

Affiliations
Randomized Controlled Trial

Macular hole closure patterns associated with different internal limiting membrane flap techniques

Tommaso Rossi et al. Graefes Arch Clin Exp Ophthalmol. 2017 Jun.

Abstract

Purpose: To compare the anatomic and functional outcome of two variants of the inverted internal limiting membrane (I-ILM) flap technique for idiopathic macular holes (IMH) larger than 400 µm.

Methods: Twenty-seven consecutive patients undergoing PPV for IMH were randomly assigned to different variants of I-ILM technique: the Cover group included 14 patients in which the I-ILM was folded upside-down over the MH as a single layer while the Fill group enrolled 13 patients in which the I-ILM was folded within the MH in multiple layers.

Results: MH closed in 12/14 Cover and in 13/13 Fill eyes (84.6 vs. 100%, p = 0.14; n.s.). Vision at 1 month was Snellen 0.44 ± 0.17 vs. 0.28 ± 0.21 (p = 0.05) and 0.48 ± 0.20 vs. 0.37 ± 0.25 (n.s.) at 3 months. IS/OS line interruption width was 463 ± 385 vs. 602 ± 210 µm, respectively, at 1 month (n.s.) and 602 ± 210 vs. 563 ± 209 µm at 3 months (n.s.). The Cover group showed outer retina cystic changes more often (p < 0.01). MH over 700 µm closed in 0/2 and in 2/2 cases, respectively, in the Cover and Fill groups (0.045).

Conclusions: Cover and Fill I-ILM techniques allowed similar closure rates and post-operative vision at 3 months. The Cover group showed better anatomical restoration and vision at 1 month while the Fill technique might be more efficient in closing larger MHs.

Keywords: Inverted internal limiting membrane flap; Macular holes; Pars plana vitrectomy.

PubMed Disclaimer

References

    1. Case Rep Ophthalmol. 2014 Mar 05;5(1):83-6 - PubMed
    1. Chin Med J (Engl). 2016 Mar 5;129(5):511-7 - PubMed
    1. Ophthalmology. 2010 Oct;117(10):2018-25 - PubMed
    1. J Ophthalmol. 2016;2016:8283062 - PubMed
    1. Am J Ophthalmol. 2013 Jul;156(1):125-131.e1 - PubMed

Publication types