Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;103(3):717-724.
doi: 10.1016/j.athoracsur.2016.12.018. Epub 2017 Feb 4.

Changes in End-Organ Function in Patients With Prolonged Continuous-Flow Left Ventricular Assist Device Support

Affiliations

Changes in End-Organ Function in Patients With Prolonged Continuous-Flow Left Ventricular Assist Device Support

Daisuke Yoshioka et al. Ann Thorac Surg. 2017 Mar.

Abstract

Background: Few studies have evaluated the long-term effects of continuous blood flow with reduced pulsatility on end-organ function.

Methods: Between May 2004 and December 2015, 469 patients underwent continuous-flow left ventricular assist device (LVAD) implantation at our center. Our study included 59 (13%) patients who were supported with an LVAD for a minimum of 3 years. We evaluated postoperative renal function and hepatic function at 1 and 6 months, and 1, 2, and 3 years after implantation in those 59 patients.

Results: The patients' mean age was 63 ± 13 years, 81% were male, 53% had an ischemic cause of heart failure, and 68% underwent LVAD implantation as destination therapy. All laboratory determinations showed significant improvements at 1 month after the procedure. Hepatic values remained in a normal range for up to 3 years, although renal function improvement was predominantly transient. One month after implantation, the mean estimated glomerular filtration rate (eGFR) was improved from 58.2 ± 27.9 to 77.7 ± 33.5 mL/min/1.73 m2. However, 46 (78%) patients showed a gradual decline in eGFR to only 1.7% above the preoperative value after 3 years (p = 0.67 vs baseline). The risk factors for impaired renal function after long-term support were age 60 years or older, ischemic cause, and late right heart failure.

Conclusions: Continuous-flow LVAD improves renal and hepatic functions in patients with advanced heart failure. However, in most, the initial improvement in renal function is largely transient and returns to baseline after a prolonged support period.

PubMed Disclaimer

LinkOut - more resources