Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2017 Aug;26(8):840-845.
doi: 10.1016/j.hlc.2016.12.003. Epub 2017 Jan 24.

Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Lower Surgical Risk Scores: A Systematic Review and Meta-Analysis of Early Outcomes

Affiliations
Meta-Analysis

Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Lower Surgical Risk Scores: A Systematic Review and Meta-Analysis of Early Outcomes

Sameer Arora et al. Heart Lung Circ. 2017 Aug.

Abstract

Background: The results from the PARTNER 2 trial showed the feasibility of transcatheter aortic valve replacement (TAVR) in intermediate surgical risk patients. Although low risk clinical trials will take time to conclude, some data has emerged comparing TAVR with surgical aortic valve replacement (SAVR) in lower risk patients.

Methods: A Medline search was conducted using standard methodology to search for studies reporting results comparing TAVR and SAVR. Studies were included if the overall mean Society of Thoracic Surgeons Score was less than 4% (or equivalent Euroscore). A meta-analysis comparing the 30-day risk of clinical outcomes between TAVR and SAVR in the lower surgical risk population was conducted.

Results: A total of four studies, including one clinical trial and three propensity-matched cohort studies met the inclusion criteria. Compared to SAVR, TAVR had a lower risk of 30-day mortality (RR 0.67, 95% CI 0.41, 1.10), stroke (RR 0.60, 95% CI 0.30, 1.22), bleeding complications (RR 0.51, 95% CI 0.40, 0.67) and acute kidney injury (RR 0.66, 95% CI 0.47, 0.94). However, a higher risk of vascular complications (RR 11.72, 95% CI 3.75, 36.64), moderate or severe paravalvular leak (RR 5.04, 95% CI 3.01, 8.43), and permanent pacemaker implantations (RR 4.62, 95% CI 2.63, 8.12) was noted for TAVR.

Conclusion: Among lower risk patients, TAVR and SAVR appear to be comparable in short term outcomes. Additional high quality studies among patients classified as low risk are needed to further explore the feasibility of TAVR in all surgical risk patients.

Keywords: Aortic stenosis; Low risk; SAVR; TAVR.

PubMed Disclaimer