Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2017 Aug;33(8):1125-1131.
doi: 10.1007/s10554-017-1088-0. Epub 2017 Feb 7.

Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale

Affiliations
Comparative Study

Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale

Jiang-Chun He et al. Int J Cardiovasc Imaging. 2017 Aug.

Abstract

To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ2=5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

Keywords: Patent foramen ovale; Sodium bicarbonate; Transesophageal echocardiography; Transthoracic contrast echocardiography; Vitamin B6.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Neurology. 1979 Mar;29(3):317-22 - PubMed
    1. Eur J Echocardiogr. 2004 Jun;5(3):176-81 - PubMed
    1. J Am Coll Cardiol. 2004 Aug 18;44(4):750-8 - PubMed
    1. Eur J Echocardiogr. 2004 Dec;5(6):449-52 - PubMed
    1. Cardiovasc Ultrasound. 2014 May 22;12 :16 - PubMed

MeSH terms

LinkOut - more resources