Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2018 Mar:168:509-531.
doi: 10.1016/j.neuroimage.2017.01.067. Epub 2017 Feb 5.

MRI and MRS of the human brain at magnetic fields of 14T to 20T: Technical feasibility, safety, and neuroscience horizons

Affiliations
Review

MRI and MRS of the human brain at magnetic fields of 14T to 20T: Technical feasibility, safety, and neuroscience horizons

Thomas F Budinger et al. Neuroimage. 2018 Mar.

Abstract

The three goals of this paper are: 1) to evaluate the improvements in technology for increasing magnetic flux density (magnetic field) to 14T in the next few years and eventually to 20T; 2) to highlight neuroscience opportunities enabled by these advances; and, 3) to evaluate the physiological and biophysical effects associated with MRI at very high performance levels. Substantial recent advances in magnet technology including superconductor developments enable neuroscience goals that are not obtainable at contemporary magnetic fields. Ten areas of brain neuroscience include potential improvements in resolution for functional MRI(BOLD), diffusion weighted MRI, tractography, susceptibility weighted MR, neuronal architecture patterns related to human behavior, proton spectroscopy of small brain biochemicals, chemical exchange saturation transfer (CEST), dynamic contrast enhanced MRI, brain energy metabolism using 13C, 17O, and 31P; and brain electrolyte physiology using 23Na, 35Cl, and 39K. Physiological phenomena and safety aspects include: absorbed RF power, acoustic sound pressure levels, induced electric fields, Lorentz forces, magnetohydrodynamic forces, and biophysical phenomena in cells and tissues. Where feasible, effects are quantified for magnetic fields beyond 7T with the conclusion that there are no foreseen barriers either in the technical or human safety aspects of brain MRI and MRS at fields up to 20T. This conclusion is conditioned on results of recommended experiments to verify the predicted level of physiological effects beyond 9.4T. This technology is predicted to enable quantification of biochemical components of the functioning brain not detectable heretofore.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources