Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve: The UK & Ireland Evolut R Implanters' Registry
- PMID: 28183467
- DOI: 10.1016/j.jcin.2016.11.025
Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve: The UK & Ireland Evolut R Implanters' Registry
Abstract
Objectives: The authors present the UK and Irish real-world learning curve experience of the Evolut R transcatheter heart valve.
Background: The Evolut R is a self-expanding, repositionable, and fully recapturable second-generation transcatheter heart valve with several novel design features to improve outcomes and reduce complications.
Methods: Clinical, procedural, and 30-day outcome data were prospectively collected for the first 264 patients to receive the Evolut R valve in the United Kingdom and Ireland.
Results: A total of 264 consecutive Evolut R implantations were performed across 9 centers. The mean age was 81.1 ± 7.8 years, and the mean logistic European System for Cardiac Operative Risk Evaluation score was 19.9 ± 13.7%. Procedural indications included aortic stenosis (72.0%), mixed aortic valve disease (17.4%), and failing aortic valve bioprostheses (10.6%). Conscious sedation was used in 39.8% of patients and transfemoral access in 93.6%. The procedural success rate was 91.3%, and paravalvular leak immediately after implantation was mild or less in 92.3%. Major complications were rare: cardiac tamponade in 0.4%, conversion to sternotomy in 0.8%, annular rupture in 0.0%, coronary occlusion in 0.8%, major vascular in 5.3%, acute kidney injury in 6.1%, new permanent pacemaker implantation in 14.7%, and procedure-related death in 0.0%. At 30-day follow-up, survival was 97.7%, paravalvular leak was mild or less in 92.3%, and the stroke rate was 3.8%.
Conclusions: This registry represents the largest published real-world experience of the Evolut R valve. The procedural success rate was high and safety was excellent, comparable with previous studies of the Evolut R valve and other second-generation devices. The low rate of complications represents an improvement on first-generation devices.
Keywords: Evolut R; aortic stenosis; complication; outcome; transcatheter aortic valve replacement; transcatheter heart valve.
Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Early Outcomes of the Evolut R Transcatheter Aortic Valve: A New Technology Between Achieved Goals and Desirable Improvements.JACC Cardiovasc Interv. 2017 Feb 13;10(3):283-285. doi: 10.1016/j.jcin.2016.12.029. JACC Cardiovasc Interv. 2017. PMID: 28183468 No abstract available.
Publication types
MeSH terms