Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Apr;33(4):427-433.
doi: 10.1016/j.dental.2017.01.003. Epub 2017 Feb 6.

In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns

Affiliations

In-vitro fatigue and fracture testing of CAD/CAM-materials in implant-supported molar crowns

Verena Preis et al. Dent Mater. 2017 Apr.

Abstract

Objective: To investigate the fatigue and fracture resistance of different CAD/CAM-materials as implant- or tooth-supported molar crowns with respect to the clinical procedure (screwed/bonded restoration).

Methods: 168 crowns were fabricated from different CAD/CAM-materials (n=8/material): ZLS (zirconia-reinforced lithium silicate ceramic; Suprinity, Vita-Zahnfabrik), COB (composite; Brilliant Crios, Coltene), COL (composite; Lava Ultimate, 3M Espe), PMV/PPV (polyether ether ketone (PEEK)+milled composite veneer/composite paste veneer; BioHPP+HIPC veneer/Crealign veneer, Bredent), COH (composite; Block HC, Shofu), and ZIR (zirconia; IPS e.max ZirCAD, Ivoclar-Vivadent) as reference. Three groups were designed simulating the following clinical procedures: (a) chairside procedure ([CHAIR] implant crown bonded to abutment), (b) labside procedure ([LAB] abutment and implant crown bonded in laboratory, screwed chairside), and (c) reference ([TOOTH] crowns bonded on human teeth). Combined thermal cycling and mechanical loading (TCML) were performed simulating a 5-year clinical situation. Fracture force was determined and failures were documented. Data were statistically analyzed (Kolmogorov-Smirnov-test, one-way-ANOVA; post-hoc-Bonferroni, α=0.05).

Results: All crowns of group LAB-PPV showed cracks after TCML. The other groups survived fatigue testing without failures. Fracture forces varied between 921.3N (PPV) and 4817.8N (ZIR) [CHAIR], 978.0N (COH) and 5081.4N (ZIR) [LAB], 746.7N (PPV) and 3313.5N (ZIR) [TOOTH]. Significantly (p<0.05) different fracture values were found between materials in all three groups. Only ZLS crowns provided no significant (p>0.05) differences between the individual groups.

Significance: Different ceramic and resin-based materials partly performed differently in implant or tooth situations. Individual resin-based materials (PPV, COB, COH) were weakened by inserting a screw channel. Most CAD/CAM-materials may be clinically applied in implant-supported crowns without restrictions. ​.

Keywords: Abutment; CAD/CAM; Chewing simulation; Composite; Fracture resistance; Implant crown; PEEK; Zirconia; Zirconia-reinforced lithium silicate.

PubMed Disclaimer

LinkOut - more resources