. 2017 May;153(5):1033-1042.
doi: 10.1016/j.jtcvs.2016.12.031. Epub 2017 Jan 11.

Remodeling root repair with an external aortic ring annuloplasty

Affiliations
Free article
Observational Study

Remodeling root repair with an external aortic ring annuloplasty

Emmanuel Lansac et al. J Thorac Cardiovasc Surg. 2017 May.
Free article

Abstract

Objective: Although the remodeling technique provides the most dynamic valve-sparing root replacement, a dilated annulus (>25 mm) is a risk factor for failure. Aortic annuloplasty aims to reduce the annulus diameter, thus increasing coaptation height to protect the repair. The results of 177 patients with remodeling and external aortic ring annuloplasty were studied.

Methods: Data were collected from the Aortic Valve repair InternATiOnal Registry. Preoperative aortic insufficiency grade 3 or greater was present in 79 patients (44.7%). The valve was bicuspid in 59 patients (33.3%). External annuloplasty was performed through a homemade Dacron ring (56) or a dedicated expansible aortic ring (121).

Results: Thirty-day mortality was 2.9% (5). Mean follow-up was 41.1 ± 36.4 months. For the whole series, freedom from valve-related reoperation, aortic insufficiency grade 3 or greater, aortic insufficiency grade 2 or greater, and major adverse valve-related events were 89.5%, 90.5%, 77.4%, and 86.6% at 7 years, respectively, with similar results for tricuspid and bicuspid valves. Since 2007, systematic use of calibrated expansible ring annuloplasty, followed 1 year later by systematic cusp effective height assessment, significantly increased 7-year freedom from valve-related reoperation, aortic insufficiency grade 3 or greater, and major adverse valve-related events up to 99.1% ± 0.9% (P = .017), 100% (P = .026), and 96.3% ± 1.8% (P = .035), respectively, whereas freedom from aortic insufficiency grade 2 or greater remained unaffected (78.1% ± 7.6%). Calibrated annuloplasty and effective height assessment were identified as protective factors from reoperation: hazard ratio, 0.13; 95% confidence interval, 0.02-1.06; P = .057 and hazard ratio, 0.11; 95% confidence interval, 0.01-0.95; P = .044, respectively.

Conclusions: The standardization of remodeling root repair with calibrated expansible aortic ring annuloplasty and cusp effective height assessment improves valve repair outcomes.

Keywords: aortic annuloplasty; aortic ring; effective height; remodeling; valve repair; valve sparing.

PubMed Disclaimer

Comment in

MeSH terms

Substances