Rate of humidifier and humidifier disinfectant usage in Korean children: A nationwide epidemiologic study
- PMID: 28189074
- DOI: 10.1016/j.envres.2017.01.030
Rate of humidifier and humidifier disinfectant usage in Korean children: A nationwide epidemiologic study
Abstract
In South Korea, a cluster of humidifier disinfectant-induced lung injury (HDLI) cases developed between 2006 and 2011. There are no existing reports regarding the rate of humidifier disinfectant (HD) usage in the general population of Korean children. The purpose of this study was to investigate the rate of humidifier and HD usage in the general population of Korean children. This is a general population-based birth cohort multicenter study, Panel Study of Korean Children (PSKC) from 2008, a humidifier and HD-related questionnaire administered to 1577 subjects (809 male, 768 female) in 2015 (n=1577). The questionnaire consisted of four categories (humidifier usage, HD usage, exposure duration, and type of HD brands). A total of 75.6% (1192/1577) had used a humidifier, and the rate of HD usage was found to be 31.1% (409/1316). Polyhexamethylene guanidine (PHMG), used as a disinfectant, was found to have the highest usage rate (62.0%). HD was used for less than 3 months of the entire lifetime of most of the subjects. In conclusion, approximately 30% of young Korean children were exposed to HD. PHMG-containing HD was the most commonly used. These results suggest that a nationwide epidemiologic investigation is needed urgently, and children exposed to HD should be investigated regarding their status of lung injury, including a pulmonary function test. Moreover, a long-term follow-up period may be required to evaluate HD usage-associated lung injury.
Keywords: Children; Disinfectants; Humidifier; Nationwide.
Copyright © 2017 Elsevier Inc. All rights reserved.
Similar articles
-
Types of household humidifier disinfectant and associated risk of lung injury (HDLI) in South Korea.Sci Total Environ. 2017 Oct 15;596-597:53-60. doi: 10.1016/j.scitotenv.2017.04.040. Epub 2017 Apr 14. Sci Total Environ. 2017. PMID: 28415004
-
Humidifier Disinfectant Consumption and Humidifier Disinfectant-Associated Lung Injury in South Korea: A Nationwide Population-Based Study.Int J Environ Res Public Health. 2021 Jun 6;18(11):6136. doi: 10.3390/ijerph18116136. Int J Environ Res Public Health. 2021. PMID: 34204162 Free PMC article.
-
Humidifier disinfectant and use characteristics associated with lung injury in Korea.Indoor Air. 2019 Sep;29(5):735-747. doi: 10.1111/ina.12585. Epub 2019 Jul 31. Indoor Air. 2019. PMID: 31278778
-
Adverse health effects of humidifier disinfectants in Korea: lung toxicity of polyhexamethylene guanidine phosphate.J Toxicol Sci. 2016;41(6):711-717. doi: 10.2131/jts.41.711. J Toxicol Sci. 2016. PMID: 27853099 Review.
-
Roots of the Large-Scale Household Humidifier Disinfectant Poisoning Tragedy: Regulatory and Surveillance Shortcomings in Korea.J Korean Med Sci. 2025 Apr 21;40(15):e144. doi: 10.3346/jkms.2025.40.e144. J Korean Med Sci. 2025. PMID: 40259726 Free PMC article. Review.
Cited by
-
Psychological Responses among Humidifier Disinfectant Disaster Victims and Their Families.J Korean Med Sci. 2019 Jan 16;34(4):e29. doi: 10.3346/jkms.2019.34.e29. eCollection 2019 Jan 28. J Korean Med Sci. 2019. PMID: 30686951 Free PMC article.
-
Evaluation of the long-term effect of polyhexamethylene guanidine phosphate in a rat lung model using conventional chest computed tomography with histopathologic analysis.PLoS One. 2021 Sep 7;16(9):e0256756. doi: 10.1371/journal.pone.0256756. eCollection 2021. PLoS One. 2021. PMID: 34492061 Free PMC article.
-
Polyhexamethylene Guanidine Phosphate Enhanced Procoagulant Activity through Oxidative-Stress-Mediated Phosphatidylserine Exposure in Platelets.Toxics. 2024 Jan 8;12(1):50. doi: 10.3390/toxics12010050. Toxics. 2024. PMID: 38251006 Free PMC article.
-
Effects of Psychotherapy on the Problem Behaviors of Humidifier Disinfectant Survivors: The Role of Individual Characteristics and Adaptive Functioning.Healthcare (Basel). 2023 Aug 1;11(15):2179. doi: 10.3390/healthcare11152179. Healthcare (Basel). 2023. PMID: 37570419 Free PMC article.
-
Health Effects Associated With Humidifier Disinfectant Use: A Systematic Review for Exploration.J Korean Med Sci. 2022 Aug 22;37(33):e257. doi: 10.3346/jkms.2022.37.e257. J Korean Med Sci. 2022. PMID: 35996934 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical