MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences

Affiliations
Comparative Study

MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences

Giovanni Foti et al. Radiol Med. 2017 May.

Abstract

Purpose: To compare the diagnostic accuracy of three-dimensional (3D) fast spin echo (FSE) intermediate-weighed (IW-3D) and 3D hybrid double-echo steady-state T1-weighted sequences (Hy-3D) and two-dimensional (FSE) images (2D) at shoulder MR arthrography (MRA).

Materials and methods: Institutional review board approval was obtained and informed consent was waived for this retrospective study. From September 2011 to October 2014, 102 patients who had undergone 1.5 Tesla MRA of the shoulder, including conventional 2D-FSE and IW-3D and Hy-3D images were included in our study. The mean interval between MRA and surgery was 21 days (range 2-70 days). MR images were retrospectively and independently reviewed by two experienced radiologists blinded to the clinical and surgical data. Supraspinatus tendon (SST), infraspinatus tendon (IST) and subscapularis tendon (SCT) tears, as well as antero-inferior, superior and posterior labral lesions were assessed, using surgery as the reference standard. Each reader's performance in assessing rotator cuff and labrum abnormalities was evaluated using the area under the receiver operating characteristic curve (AUC) and 95% confidence intervals (CIs). The difference was evaluated using a univariate z test. The sensitivity, specificity, positive predictive values (PPV), negative predictive values (NPV) and accuracy (Acc) for all types of rotator cuff tears and labral lesions were calculated. A value of p < 0.05 was considered statistically significant. Inter-observer agreement was calculated using kappa statistics.

Results: The difference of diagnostic accuracy achieved was not significant (p > 0.05). In particular, differences in AUC values ranged from 0.002 (p = 0.98) to 0.014 (p = 0.82) as regards the comparison between 2D and IW-3D images, from 0.002 (p = 0.98) to 0.034 (p = 0.08) concerning the comparison between 2D and Hy-3D images and from 0.010 (p = 0.82) to 0.032 (p = 0.09) when comparing Hy-3D to IW-3D images. Accuracy values in evaluating RC lesions and labral lesions were 95.1, 92.1, 91.2, 93.1, 93.1 and 94.1% by reading 2D, Hy-3D and IW-3D images, respectively. The difference of diagnostic accuracy achieved using the datasets analyzed was not significant (p > 0.05). Inter-observer agreement was very good for each of the datasets that were evaluated, with near-perfect agreement for 2D dataset (k = 0.86), Hy-3D (k = 0.81) and IW-3D (k = 0.83).

Conclusions: The accuracy of IW-3D and Hy-3D images was not significantly higher than the 2D sequences in evaluating RC and labral lesions.

Keywords: 3D sequences; Glenoid labrum; Magnetic resonance arthrography; Rotator cuff; Shoulder.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Magn Reson Imaging. 2007 Jul;26(1):118-22 - PubMed
    1. Acta Radiol. 2013 Feb 1;54(1):75-82 - PubMed
    1. AJR Am J Roentgenol. 2015 Nov;205(5):1056-60 - PubMed
    1. AJR Am J Roentgenol. 2004 Dec;183(6):1729-35 - PubMed
    1. Orthop J Sports Med. 2014 Sep 15;2(9):2325967114549541 - PubMed

Publication types

LinkOut - more resources