Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Feb 14:33:143-157.
doi: 10.22203/eCM.v033a11.

A chlorhexidine-releasing epoxy-based coating on titanium implants prevents Staphylococcus aureus experimental biomaterial-associated infection

Affiliations
Free article

A chlorhexidine-releasing epoxy-based coating on titanium implants prevents Staphylococcus aureus experimental biomaterial-associated infection

M Riool et al. Eur Cell Mater. .
Free article

Abstract

Prevention of biomaterial-associated infections (BAI) remains a challenging problem, in particular due to the increased risk of resistance development with the current antibiotic-based strategies. Metallic orthopaedic devices, such as non-cemented implants, are often inserted under high mechanical stress. These non-cemented implants cannot be protected by e.g. antibioticreleasing bone cement or other antimicrobial approaches, such as the use of bioactive glass. Therefore, in order to avoid abrasion during implantation procedures, we developed an antimicrobial coating with great mechanical stability for orthopaedic implants, to prevent Staphylococcus aureus BAI. We incorporated 5 and 10 wt % chlorhexidine in a novel mechanically stable epoxy-based coating, designated CHX5 and CHX10, respectively. The coatings displayed potent bactericidal activity in vitro against S. aureus, with over 80 % of the release (19 µg/cm2 for CHX5 and 41 µg/cm2 for CHX10) occurring within the first 24 h. In mice, the CHX10 coating significantly reduced the number of CFU (colony forming units), both on the implants and in the peri-implant tissues, 1 d after S. aureus challenge. The CHX10-coated implants were well-tolerated by the animals, with no signs of toxicity observed by histological analysis. Moreover, the coating significantly reduced the frequency of culture-positive tissues 1 d, and of culture-positive implants 1 and 4 d after challenge. In summary, the chlorhexidine-releasing mechanically stable epoxy-based CHX10 coating prevented implant colonisation and S. aureus BAI in mice and has good prospects for clinical development.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources