Bicortical facet screws as a new option for posterior C2 fixation: anatomical study and clinical experience
- PMID: 28204927
- DOI: 10.1007/s00586-017-4997-7
Bicortical facet screws as a new option for posterior C2 fixation: anatomical study and clinical experience
Abstract
Purpose: C2 fixation is a demanding procedure, particularly in patients with variants of C1-C2 anatomy. The inferior articular process (IAP) of the axis can be an alternative for screw placement. We report the results of a CT study of C2 IAP anatomy and we present the clinical experience of 28 patients operated with this technique.
Methods: Anatomical study: 50 CT angiographies of the vertebral arteries (VA) were used for this study and, therefore, 100 IAPs were considered. We measured on the axial and sagittal planes the length, height and width of the facet, the distance between the anterior cortex and the VA and the distance between the screw entry point and the VA. We also measured the angle between the sagittal plane and the external tangent line of the VA.
Clinical report: 28 patients were treated with C2 IAP screws at the Spine Surgery Department of the University Hospital in Lyon, France, from January 2014 to January 2016.
Results: Anatomical study: the mean length of C2 IAP was 12 ± 2 mm, the mean distance between the anterior cortical layer and the VA was 5.2 ± 1.4 mm, and the mean angle we found was 0.2° ± 5.3°.
Clinical report: 16 of the 28 patients presented post-traumatic C1-C2 instability, 8 patients presented degenerative disease, 1 patient was treated for pseudoarthrosis, 1 for tumour, 1 for OPLL and 1 for rheumatoid arthritis. All the screws were correctly positioned and there was no VA injury.
Conclusion: IAP screws can represent a safe alternative option for C2 fixation.
Keywords: Atlanto-axial instability; Axis fixation; C1–C2 fixation; Cervical trauma; Occipito-cervical fusion.
Similar articles
-
[Harms technique of C1-C2 fixation with polyaxial screws and rods].Acta Chir Orthop Traumatol Cech. 2005;72(1):22-7. Acta Chir Orthop Traumatol Cech. 2005. PMID: 15860148 Czech.
-
Anatomical considerations for the placement of cervical transarticular screws.J Neurosurg Spine. 2011 Jan;14(1):114-21. doi: 10.3171/2010.9.SPINE1066. Epub 2010 Dec 17. J Neurosurg Spine. 2011. PMID: 21166487
-
Multiplanar reconstructions of helical computed tomography in planning of atlanto-axial transarticular fixation.Eur Spine J. 2005 Jun;14(5):493-500. doi: 10.1007/s00586-004-0838-6. Epub 2005 Mar 8. Eur Spine J. 2005. PMID: 15754214 Free PMC article.
-
Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases.Spine (Phila Pa 1976). 2011 Jan 1;36(1):3-8. doi: 10.1097/BRS.0b013e3181c97dc7. Spine (Phila Pa 1976). 2011. PMID: 20693942
-
Posterior atlanto-axial fixation with polyaxial C1 lateral mass screws and C2 pars screws.Acta Neurochir (Wien). 2009 Mar;151(3):223-9; discussion 229. doi: 10.1007/s00701-009-0198-4. Epub 2009 Feb 20. Acta Neurochir (Wien). 2009. PMID: 19229471
Cited by
-
Application of C2 subfacetal screws for the management of atlantoaxial dislocation in patients with Klippel-Feil syndrome characterized by a narrow C2 pedicle and high-riding vertebral artery.J Orthop Surg Res. 2022 Nov 16;17(1):495. doi: 10.1186/s13018-022-03391-z. J Orthop Surg Res. 2022. PMID: 36384627 Free PMC article.
-
C2 pars interarticularis length on the side of high-riding vertebral artery with implications for pars screw insertion.Sci Rep. 2025 May 28;15(1):18639. doi: 10.1038/s41598-025-02174-w. Sci Rep. 2025. PMID: 40436927 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous