Abstract

Introduction. We aimed to assess the efficacy and safety of digital subtraction angiography (DSA) and super-selective mesenteric artery embolization (SMAE) in managing lower GI bleeding (LGIB). Method. A retrospective case series of patients with LGIB treated with SMAE in our health service. Patients with confirmed active LGIB, on either radionuclide scintigraphy (RS) or contrast-enhanced multidetector CT angiography (CE-MDCT), were referred for DSA +/- SMAE. Data collected included patient characteristics, screening modality, bleeding territory, embolization technique, technical and clinical success, short-term to medium-term complications, 30-day mortality, and progression to surgery related to procedural failure or complications. Results. There were fifty-five hospital admissions with acute unstable lower gastrointestinal bleeding which were demonstrable on CE-MDCT or RS over a 31-month period. Eighteen patients proceed to embolization, with immediate success in all. Eight patients (44%) had clinical rebleeding after intervention, warranting repeated imaging. Only one case (5.6%) demonstrated radiological rebleeding and was reembolized. Complication rate was excellent: no bowel ischaemia, ischaemic stricture, progression to surgery, or 30-day mortality. Conclusion. SMAE is a viable, safe, and effective first-line management for localised LGIB. Our results overall compare favourably with the published experiences of other institutions. It is now accepted practice at our institution to manage localised LGIB with embolization.

PubMed Disclaimer

Conflict of interest statement

The authors declare that there are no competing interests regarding the publication of this study.

Figures

Figure 1
Figure 1
Presumptive aetiology of LGIB.
Figure 2
Figure 2
Diagnostic imaging modality performed.
Figure 3
Figure 3
Location of bleeding sites by vascular territory.
Figure 4
Figure 4
Super-selective embolization: (a) before and (b) after coil deployment.

Similar articles

Cited by

References

    1. Edelman D. A., Sugawa C. Lower gastrointestinal bleeding: a review. Surgical Endoscopy. 2007;21(4):514–520. doi: 10.1007/s00464-006-9191-7. - DOI - PubMed
    1. Barnert J., Messmann H. Diagnosis and management of lower gastrointestinal bleeding. Nature Reviews Gastroenterology and Hepatology. 2009;6(11):637–646. doi: 10.1038/nrgastro.2009.167. - DOI - PubMed
    1. Farrell J. J., Friedman L. S. Review article: the management of lower gastrointestinal bleeding. Alimentary Pharmacology & Therapeutics. 2005;21(11):1281–1298. doi: 10.1111/j.1365-2036.2005.02485.x. - DOI - PubMed
    1. Funaki B. Superselective embolization of lower gastrointestinal hemorrhage: a new paradigm. Abdominal Imaging. 2004;29(4):434–438. - PubMed
    1. Rider P., Beck D., Timmcke A., Hicks T., Whitlow C., Margolin D. Mesenteric embolization: a safe and efficacious treatment modality of lower gastrointestinal hemorrhage. Proceedings of the Annual Meeting of the American Society of Colon and Rectal Surgeons; May 2009; Hollywood, Fla, USA. pp. 794–795. - DOI

LinkOut - more resources